26 Installation
MAN102D-V1.8
8.4 WIRING
When connecting the 102D it is good practice to use shielded cable. The shield
should be connected to earth at one end of the cable. The other end of the shield
should not be connected.
This wiring practice is mandatory in order to comply with the requirements for
Electromagnetic Compatibility as per EMC-Directive 2014/30/EU of the Council of
the European Community.
8.5 MAINTENANCE
All printed circuit boards must be repaired by a Contrec Ltd.
8.6 TERMINAL DESIGNATIONS
J2 - Frequency Input and Optional DC Power.
FR -
Pulse (-) / Coil Frequency Input
FR +
Pulse (+) / Coil Frequency Input
J5 - Remote Switches.
1
Sw1 ( Accum Total )
2
Gnd
3
Sw2 ( Reset )
4
Calibration entry
5
Gnd
6
Gnd
7
Sw3 ( Program )