Problem
Cause
Solution
Air does not come out
of the vent in the RC
handle body.
Twinline hose is clogged or
pinched.
Disconnect the Twinline hose
and ensure that it is not
clogged.
Control valve RCV does
not open.
Safety drain valve is still
open.
Close the safety drain valve.
Air feed to abrasive
blasting machine is not
sufficient.
Dismantle the control valve, all
parts should rotate freely.
RC control valve RCV
does not close.
RC handle channels are
clogged.
Remove the key and clean it.
Incorrect connection of
TWINLINE hose.
Check connections and change
them if they are incorrect.
Control valve failure.
Disassemble the valve and
ensure that it functions
properly.