© 2012, Continuum Footspas, LLC
March, 2012
Operating Instructions for I-Fill
™
System (Auto Fill)
(Auto Fill is a Factory Installed Option)
Step #1) LIFT AND TURN
chrome handle of the Hot/Cold water valve (6) upwards. Handle is located
in front of spa. Make sure drain Pop-Up (13) is in the up position allowing water to drain out of the
basin.
Step #2)
Press chrome “I-Fill” button to begin water flow. (If spa has optional drain pump, one must
also start pump by pressing “Drain” button). When water reaches desired temperature; turn Drain
Handle (5) to lower Pop-Up (13). Basin will continue to fill. NOTE: Every time “I-Fill” button is pressed,
a short beep may be heard. This is perfectly normal.
Water will automatically shut off upon reaching preset level and jet will begin running. Jet may be shut
off at any time by pressing “I-Fill” button.
Press and hold “I-Fill” button to add additional water to basin.
NOTE: If water falls below sensor electrodes located on jet body (11), jet will turn off. Additional water
must be added to cover sensors allowing jet to turn on.
Adjusting Sensor Delay Time Setting
There is a control box located underneath the black, right side (when facing the spa) shroud or side
panel. Removing a shroud or panel is quite easy.
On the side of the control box is a green LED light. Next to it is a blue circle control. Using a small
screwdriver, one may turn the arrow inside the circle from 5 seconds to 55 second. This is the time
delay for shutting off the water after the water reaches the sensor electrodes located on the
jet body (11).
While the time delay has been preset at the factory, depending on water pressure and other factors,
this adjustment allows one to control the level of the water before the jet turns on.