© 2012, Continuum Footspas, LLC
March, 2012
End of Each Day Cleaning Procedures
1. Remove
the cover and impeller from the NoPipe™ Jet. No tools are required.
Simply grip the cover and gently twist off. To replace, position cover on front of jet, twist gently
to lock. Turn “left-handed” screw to remove impeller.
2
.
Clean
the screen and the area behind it with a brush, liquid soap and water to remove all
visible residue and replace properly cleaned screens and impellers.
3. Fill
the basin with warm water and chelating detergent and circulate the chelating detergent through
the spa system for 5-10 minutes (follow manufacturer’s instructions).
4. Drain
the soapy solution and rinse the basin.
5. Refill the basin
with clean water
and circulate
the correct amount (read the label for mixing
instructions) of the EPA Registered Liquid Disinfectant (Splish Splash is strongly recommended)
through the basin for 10 minutes.
6. Drain, rinse
and wipe dry with a clean
paper
towel.
7.
Allow the basin to dry completely.
At least once each week overnight procedures:
After completing the End of Each Day procedures:
1.
Do not drain the liquid disinfectant solution - Turn off the unit and leave the disinfecting solution in
your pedicure chair at least 6 to 10 hours.
2.
In the morning drain and rinse.
3.
Refill the basin with clean water and flush the system.
YOUR ARE REQUIRED TO CHECK WITH YOUR STATE BOARD FOR
MANDATORY CLEANING AND DISINFECTING REQUIREMENTS AND PROCEDURES.
Pedicure Chairs from
Continuum
®
Footspas