Optional features explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED.
Pairing with the app:
This function is used to pair therM
2
to the therM2 app.
WiFi set-up:
This function is used to connect therM
2
with the WiFi network.
Switching differential:
This function allows you to increase the switching differential of
the thermostat. The default is 0.5°C which means that with a set temperature of 20°C, the
thermostat will switch the heating on at 19.5°C and off at 20.0°C. With a 1°C differential,
the heating will switch on at 19.0°C and off at 20.0°C.
Away temperature:
This is the temperature maintained when the thermostat is in away
mode. The range is 7 - 17°C. The default is 12°C and is suitable for most applications.
Output delay:
To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Temperature up / down limit:
This function allows you to limit the use of the up and
down temperature arrow keys. This limit is also applicable when the thermostat is locked
and so allows you to give others limited control over the heating system.
Sensor selection:
On therM
2
, you can select which sensor should be used. You can select
between air temperature only, floor temperature, or both. When you enable both sensors,
the floor sensor is used as a floor limiting sensor and is designed to prevent the
floor from overheating.
Summary of Contents for therM2
Page 1: ...therM2...
Page 6: ...6 Section Header 6 Section Header therM2 1 2 3 4...
Page 11: ...Section Header 11 Section Header 11 therM2 Mode 1 Thermostat...
Page 12: ...12 Section Header 12 Section Header therM2 1 2 5 3 11 10 9 12 4 6 7 8...
Page 31: ...Section Header 31 Section Header 31 therM2 Mode 2 Time clock...
Page 32: ...32 Section Header 32 Section Header therM2 1 3 5 8 7 6 4 2...
Page 40: ...Model Manual REF 40 Notes 40 Model Manual REF 40 Notes 40 therM2...
Page 41: ...41 Notes 41 Notes therM2...
Page 42: ...Model Manual REF 42 Notes 42 Model Manual REF 42 Notes 42 therM2...
Page 43: ...43 Notes 43 Notes therM2...