Continental Hydraulics Installation Manual
Page 11 of 20
CEM-BPS-B
CHI 1020813 Jan 2016
LED Indications
LEDs
Description of the LED function
Identical to the READY output.
OFF: No power supply or ENABLE is not activated
ON: System is ready for opperation
Flashing: Error discovered
Only active when SENS = ON
Identical to the STATUS output.
OFF: The axis is outside the control deviation window.
ON: The axis is within the control deviation window.
1.
Chasing light (over all LEDs):
The boot loader is active. No normal
functions are possible.
2.
All LEDs flash shortly every 6 s:
An internal data error was detected
and corrected automatically! The module still works regularly. To
acknowledge the error the module has to have power cycled.
YELLOW A +
YELLOW B
Both yellow LEDs flash oppositely every 1 s:
The nonvolatile stored
parameters are inconsistent! To acknowledge the error, the data have to
be saved with the SAVE command or the corresponding button in the CHI-
PC. If the function of the module has changed via the FUNCTION
parameter, all parameters are deleted purposely and set to default values.
In this case the LEDs indicate no error, but a desired state. To
acknowledge please save.
GREEN
YELLOW A
GREEN + YELLOW
A+B