16.0 TROUBLESHOOTING 

(MILLIVOLT)

SYMPTOM

PROBLEM

TEST SOLUTION

Main burner goes out; pilot 
stays on.

Pilot 

fl

 ame is not large 

enough or not engul

fi

 ng the 

thermopile.

 

-

Turn up the pilot 

fl

 ame.

 

-

Replace pilot assembly.

Thermopile shorting.

 

-

Clean thermopile connection to the valve. Reconnect.

 

-

Replace thermopile / valve.

Remote wall switch wire is too 
long; too much resistance in 
the system.

 

-

Shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

 

-

Replace.

Main burner goes out; pilot 
goes out.

Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”
Vent is blocked

 

-

Check for vent blockage.

Vent is re-circulating

 

-

Check joint seals and installation

Flexible vent has become 
disconnected from appliance.

 

-

Re-attach to appliance.

 

-

Cap was not replaced.

Pilot goes out when the 
gas knob is released.

The gas valve has an 
interlock device which 
will not allow the pilot 
burner to be lit until 
the thermocouple 
has cooled. Allow 
approximately 60 
seconds for the 
thermocouple to cool.

System is not correctly purged

 

-

Purge the gas line.

Out of propane gas.

 

-

Fill the tank.

Pilot 

fl

 ame is not large 

enough.

 

-

Turn up the pilot 

fl

 ame.

Pilot 

fl

 ame is not engul

fi

 ng the 

thermocouple

 

-

Gently twist the pilot head to improve the 

fl

 ame pattern 

around the thermocouple.

Thermocouple shorting / faulty.

 

-

Loosen and tighten thermocouple.

 

-

Clean thermocouple and valve connection.

 

-

Replace thermocouple.

 

-

Replace valve.

Faulty valve.

 

-

Replace.

Pilot burning; no gas to 
main burner; gas knob 
is on ‘HI’; wall switch / 
thermostat is on.

Thermostat or switch is 
defective

 

-

Connect a jumper wire across the wall switch terminals; 
if main burner lights, replace switch / thermostat.

Wall switch wiring is defective.

 

-

Disconnect the switch wires & connect a jumper wire 
across terminals 1 & 3; if the main burner lights, check 
the wires for defects and/or replace wires.

Main burner ori

fi

 ce is plugged. 

 

-

Remove stoppage in ori

fi

 ce.

Faulty valve.

 

-

Replace.

Pilot goes out while 
standing; Main burner is in 
‘OFF’ position.

Gas piping is undersized.

 

-

Turn on all gas appliances and see if pilot 

fl

 ame 

fl

 utters, 

diminishes or extinguishes, especially when main burner 
ignites. Monitor appliance supply working pressure.

 

-

Check if supply piping size is to code. Correct all 
undersized piping.

Main burner 

fl

 ame is a 

blue, lazy, transparent 

fl

 ame.

Blockage in vent.

 

-

Remove blockage. In really cold conditions, ice buildup 
may occur on the terminal and should be removed as 
required.  To minimize this from happening again, it is 
recommended that the vent lengths that pass through 
unheated spaces (attics, garages, crawl spaces) be 
wrapped with an insulated mylar sleeve.  Prevent sleeve 
from sagging.  Contact your local authorized dealer for 
more information.

42.3B

!

WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, 

WITH THE GLASS DOOR OPEN OR REMOVED.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

Summary of Contents for CX70NT

Page 1: ...nt Installation and service must be performed by a qualified installer service agency or the supplier If the information in these instructions are not followed exactly a fire or explosion may result c...

Page 2: ...S 30 5 2 1 ALCOVE CLEARANCE TO COMBUSTIBLES ENCLOSURE 31 5 3 NON COMBUSTIBLE FACING MATERIAL 32 5 4 MINIMUM COMBUSTIBLE MANTEL CLEARANCES 33 5 5 NAILING TAB INSTALLATION 33 6 0 FINISHING 34 6 3 SAFETY...

Page 3: ...CLEARANCE TO COMBUSTIBLE ENCLOSURES for non combustible materials such as tile marble granite etc IMPORTANT Extra support may be required See the section MINIMUM ENCLOSURE CLEARANCES for drywall or ot...

Page 4: ...no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part has...

Page 5: ...5 W415 1540 08 04 15 EN 2 1 CX70 DIMENSIONS 33 1 8 841mm CX70 ILLUSTRATED 18 1 2 470mm 7 3 16 182mm 1 15 16 50mm GAS INLET 5 127mm 11 13 16 299mm 8 203mm 35 890mm 11 5 16 288mm 33 1 8 841mm...

Page 6: ...uld choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material othe...

Page 7: ...ng plate This appliance is not convertible for use with other gases unless a certified kit is used When the appliance is installed at elevations above 4 500 ft 1371m and in the absence of specific rec...

Page 8: ...MINIMUM AND MAXIMUM VENT LENGTHS REFERER AU MANUEL D INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS D EVACUATION MINIMALE ET MAXIMALE WOLF STEEL LTD 24 NAPOLEON ROAD BARRIE ON L4M 0G8 CANADA UN COMBU...

Page 9: ...itial installation NOTE This appliance must be installed with a continuous connection of exhaust and air intake vent pipes Utilizing alternate constructions such as a chimney as part of the vent syste...

Page 10: ...in conjunction with the various terminations use either the 5 foot 1 5m vent kit GD420 or the 10 foot 3 1m vent kit GD430 For optimum flame appearance and appliance performance keep the vent length an...

Page 11: ...VENT INSTALLATION 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM TOP VENT 33 1 8 841MM THE FIRST TWO FEET OF OUTER 8 178MM DIAMETER VENT PIPE FROM THE APPLIANCE MUST BE WRAPPED IN THE 1 25MM THIC...

Page 12: ...rade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum 12 305m above grade The maximum allowable vent length is 10 3m for a fireplace and...

Page 13: ...6mm 16 406mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m See...

Page 14: ...eet 10 7m 4 2 times the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 1 For the following symbols u...

Page 15: ...90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 6m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m Formula 1 HT VT 9 9 FT 3m 11 FT 3 4m Formula 2 HT VT 40 FT 12 2m 20 9 FT 6 4m 40 FT 12 2m Si...

Page 16: ...m Formula 2 HT VT 24 75 FT 7 5m 16 7 FT 5 1m 24 75 FT 7 5m Since both formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT...

Page 17: ...FT 1 5m V2 6 FT 1 8m V3 10 FT 3 1m VT V1 V2 V3 5FT 1 5m 6FT 1 8m 10FT 3 1m 21FT 6 4m H1 8 FT 2 4m H2 2 5 FT 0 8m HR H1 H2 8FT 2 4m 2 5FT 0 8m 10 5 FT 3 2m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5...

Page 18: ...6FT 1 8m 2FT 0 6m 8 FT 2 4m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5m HT HR HO 8FT 2 4m 8 1FT 2 5m 16 1FT 4 9m HT VT 16 1FT 4 9m 4 5FT 1 4m 20 6 FT 6 3m Formula 1 HT 3VT 3VT 3FT 0 9m x 4 5FT 1 4m...

Page 19: ...AS AND ELECTRICAL SUPPLY TO THE APPLIANCE FOR SAFE AND PROPER OPERATION OF THE APPLIANCE FOLLOW THE VENTING INSTRUCTIONS EXACTLY ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING...

Page 20: ...is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will...

Page 21: ...nt the additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent p...

Page 22: ...ving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is...

Page 23: ...A 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION A Move the appliance into position Measure the vent length required between terminal and appliance taking into account the additional length needed for the...

Page 24: ...mm margin all around Fasten to the roof Do NOT nail through the lower portion of the flashing Make weather tight by sealing with caulking Where possible cover the sides and top edges of the flashing w...

Page 25: ...ding products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is recommended that the applian...

Page 26: ...EVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A...

Page 27: ...THICKNESS TO MAINTAIN CLEARANCES FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BR...

Page 28: ...6 471mm ENCLOSURE TOP FINISHING MATERIAL ELECTRICAL CONNECTION 591 2 1511mm MIN 3 81 4 210mm 1 15 16 49mm STEEL STUD 35 1 2 902 mm STEEL STUD NON COMBUSTIBLE MATERIAL FRAMING DIMENSIONS Ref CX70 A 35...

Page 29: ...any of the black face areas of the appliance Non combustible material brick stone or ceramic tile may protrude in these areas Minimum clearance to combustible construction from appliance and vent sur...

Page 30: ...6mm COMBUSTIBLE NON COMBUSTIBLE BRICK 0 0MM IF NON COMBUSTIBLE FINISHINGISUSED SUCHASBRICK ANDSTONE 3 76mm MINIMUM 3 76mm 2 51mm 1 25mm 591 2 1511mm 78 1981mm CEILING MIN 189 16 471mm 4713 16 1214mm M...

Page 31: ...47 13 16 1214mm 1 25mm 33 1 8 841mm 42 1066mm 78 1981mm 2 51mm 3 76mm FIRESTOP ASSEMBLY STEEL STUD FRAMING NON COMBUSTIBLE MATERIAL 0 0MM IF NON COMBUSTIBLE FINISHING MATERIAL IS USED SUCH AS BRICK AN...

Page 32: ...e sides If greater projections are desired increase the clearance to the sides and top by 2 51mm for every additional 1 25mm of projection If using an optional surround the same rule applies starting...

Page 33: ...UST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 5 4 MINIMUM COMBUSTIBLE MANTEL CLEARANCES 0 3 4 7 14 16 1 2 5 6 12 7 0 1 7 MANTEL DEPTH 8 10 6 4 18 20 8 10 9 22 24 26 E D C B A TOP OF OPENING MAN...

Page 34: ...TE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING 72 1A 6 1 LOG SHIPPING BRACKET Before installing the logs yo...

Page 35: ...ss door can be removed the safety screen must be removed Lift the safety screen off the 4 pins tilt the top forward and remove from the appliance Leave a hand on the glass door during entire door remo...

Page 36: ...ce the colours will become more uniform as colour pigments burn in during the heat activated curing process Blocked burner ports can cause an incorrect flame pattern 6 4 LOG PLACEMENT 1 PIN 2 PIN A Pl...

Page 37: ...rts Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition PHAZERTM logs glow when exposed to direct flame Use only certified glowing embers and PHAZERTM logs a...

Page 38: ...OT RESET BUTTON BATTERY HOLDER COMPLETE NIGHT LIGHT BLOWER WITH RESET BUTTON W190 0048 RECEIVER BLOWER NOTE This appliance is equipped with a three prong grounding plug for protection against shock ha...

Page 39: ...ntil the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is depressed...

Page 40: ...alve clockwise to off Located behind the access panel G Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above safety information on this label I...

Page 41: ...ress the reset programming button use a small object such as a paper clip in order to reach the button marked PRG as shown in the illustration below D The battery holder will beep 3 times to indicate...

Page 42: ...le the system is on but the flame is off the flame will come on the high position A single beep will confirm reception of the command 35 8A 76 F OFF 76 F 76 F 76 F Hi FLAME OFF FLAME AT LEVEL 1 FLAME...

Page 43: ...is equipped with a CPI IPI toggle switch set the CPI IPI to CPI position to enable remote CPI operation If the switch is set to IPI then it will only work in IPI regardless of what is set on the remot...

Page 44: ...g the remote B Install 4 AA batteries ensure that the positive and negative ends correspond with those identified in the battery holder C In the case of a power outage the 3 position slider switch nee...

Page 45: ...ssure gauge tubing over the test point Gauge should read as described on the chart below Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge...

Page 46: ...hich can be distributed in the surrounding living area F Check to see that the main burner ignites completely on all openings when turned on A 5 to 10 second total light up period is satisfactory If i...

Page 47: ...is important that the pilot assembly is not painted Inspect all accessible gaskets and replace as required Access the blower if equipped and clean using a soft brush and vacuum Re assemble the various...

Page 48: ...COUPLE SUPPLIED BY WOLF STEEL LTD WARNING 10 1 NIGHT LIGHT REPLACEMENT Your appliance came equipped with our NIGHT LIGHT The light has been pre wired and can be controlled from the switch on the contr...

Page 49: ...the gasket holding the glass in place Careful not to break the glass WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CARE MUST BE TAKEN WHEN REMOVING AND DISPO...

Page 50: ...r Drywall dust will penetrate into the blower bearings causing irreparable damage Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resu...

Page 51: ...570 0135 W635 0087 HOOD CONTINENTAL LOGO DOOR ASSEMBLY LOG SUPPORT 3 PRONGE ELECTRICAL BOX W010 3070 DOOR LATCHES X4 STAND OFFS X4 1 2 3 4 8 6 13 11 13 10 13 12 13 9 13 13 13 14 SHOULDER SCREWS X4 14...

Page 52: ...VALVE TRAIN BASE W035 0404 W010 0799 PILOT ASSEMBLY LP W080 1601 PILOT BRACKET W080 1560 VALVE BRACKET W725 0026 VALVE LP W450 0036 PAL NUT 2 4 W290 0235 VENTURI HOUSING GASKET W350 0696 VENTURI HOUSI...

Page 53: ...0057 VALVE LP W290 0235 VENTURI HOUSING GASKET W350 0696 VENTURI HOUSING W750 0268 BATTERY HOUSING WIRE HARNESS 16 17 18 19 20 21 22 23 W750 0358 FEMALE X4 ON OFF JUMPER W750 0159 BLOWER WIRE HARNESS...

Page 54: ...0 15 GX70 ACCESSORIES H35F GX725WI GX427 47 48 TK35 W430 0003 MAGNET X16 TK35 YES W715 0953 TOP BOTTOM TRIM X2 TK35 W715 0952 SIDE TRIM X2 TK35 W475 1142 LS PORCELAIN PANEL PRPGX70 W475 1143 REAR PORC...

Page 55: ...ed and plugged into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer ar...

Page 56: ...me rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood th...

Page 57: ...ctor plate See RESTRICTING VENTS section if applicable Main burner flame is a blue lazy transparent flame Blockage in vent Remove blockage In extreme conditions ice buildup may occur on the terminal a...

Page 58: ...lace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch termin...

Page 59: ...Gauge should read as described on the chart below Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak tes...

Page 60: ...headaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative...

Page 61: ...sufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat e...

Page 62: ......

Reviews: