6
W415-1115 / 06.13.12
4.10A
This gas appliance should be installed and serviced by a qualifi ed installer to conform with local codes.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your
area, for example: in Massachusetts State:
•
The appliance off valve must be a “T” handle gas cock.
• The
fl exible connector must not be longer than 36“.
•
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a direct
vent sealed combustion product.
•
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
• WARNING:
This product must be installed by a licensed plumber or gas fi tter when installed within the
commonwealth of Massachusetts.
•
Un-vented room appliance shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00
through 7.00.
•
Sellers of un-vented propane or natural gas-fi red space / room appliances shall provide to each purchaser
a copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/
Webshare/installation_manuals/mass_requirements.pdf
In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1
Installation Code which can be obtained from:
American National Standards Institute Inc. or
National Fire Protection Association Inc.
1430
Broadway
Batterymarch
Park
New York, NY 10018
Quincy, MA 02269
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be
isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). When
installed with a blower the junction box must be electrically connected and grounded in accordance with local
codes. In the absence of local codes, use the current ANSI / NFPA 70 National Electric Code. In the case
where the blower is equipped with a power cord it must be connected into a properly grounded receptacle.
The grounding prong must not be removed from the cord plug.
As long as the required clearance to combustibles is maintained,
the most desirable and benefi cial location for the appliance is in the
center of a building, thereby allowing the most effi cient use of the
heat created. The location of windows, doors and the traffi c fl ow in
the room where the appliance is to be located should be considered.
* Air shortage caused by an inadequate air supply, improper log
positions, the addition of foreign or unapproved materials or the
failure to properly maintain the appliance, may result in incomplete
combustion of the fuel. Incomplete combustion results in soot being deposited inside the fi rebox as well as
surfaces outside the appliance. If any soot deposits are observed, shut off the appliance immediately and
arrange for it to be serviced by a qualifi ed technician. Incomplete combustion can also generate increased
levels of carbon monoxide (CO).
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
® (NFI) as NFI Gas
Specialists
www.nficertified.org
Summary of Contents for CWHVF31N
Page 28: ...28 W415 1115 06 13 12...