EN
W415-4084 / A / 06.01.22
27
installation
4.2 appliance vent connection - model CDVS600-1
A.
Attach the adjustable pipe to the last section of rigid pipe. Secure with
screws and seal.
B.
Install the inner fl ex pipe to the appliance. Secure with a minimum of
three screws and fl at washers when installing 3”/5”, 4”/7” or 5”/8”
venting, or six screws and fl at washers when installing 8”/10” or
8”/11” venting. Seal the joint and screw holes using Mill Pac sealant
(W573-0007) (not supplied).
C.
Run a bead of high temperature red RTV silicone sealant (W573-
0002) (not supplied) around the inside of the air intake collar. Pull the
adjustable pipe a minimum 2” (50.8mm) into the air intake collar.
19.2
INSERT
IMAGE HERE
note:
Always fi nish vent system installation with the appliance vent connection. Ensure that the sealant is not visible on the
exterior pipes once installation is completed. An optional decorative black band may be available with this appliance.
In the event that the venting must be disassembled, care must be taken to reseal the venting.
1 1/2”
(38.1mm)
Overlap
REAR VENT
1 1/4” (31.8mm)
Overlap
TOP VENT - FLEX
TOP VENT - RIGID/FLEX
#8 X 1/2”
Self Drilling
Screws
45 VENT - FLEX
45 VENT - RIGID/FLEX
#8 X 1/2”
Self Drilling
Screws
Mill-Pac Sealant
Red RTV
Silicone
2” (50.8mm)
Overlap
Mill-Pac
Sealant
#8 X 1/2”
Self Drilling
Screws
2” (50.8mm)
Overlap
Mill Pac
Sealant
#8 X 1/2”
Self Drilling
Screws
Mill-Pac
Sealant
2” (50.8mm)
Overlap
#8 X 1/2”
Self
Drilling
Screws
Mill-Pac
Sealant