13

W415-0162 / E / 03.05.04

Ensure that 2 female ends remain at the top.

Re-secure the access plate.

3.

Remove the spill switch bracket from the rear of the

adapter. Unscrew the spill switch and discard the bracket.
Attach the spill switch to the bracket supplied with the stove
and secure onto the adapter.

4.

Bring the wires through the lower hole in the adapter. 

To

pass the wires through the hole more easily, temporarily
tape the two terminals together.
5.

With the spill switch opening aligned to the back of the

stove, take hold of the adapter base and push the crimped
edge into the stove flue collar.

6.

Connect the upper wire terminals to the spill switch.

7.

Disconnect the wire lead from terminal 3 on the valve

and reconnect to the male end of the spill switch wire. Con-
nect the female end of the spill switch wire to terminal 3 on
the valve.
Leave all excess wire in an orderly manner.

For aesthetics, the adapter has been designed to ac-
cept a standard matte black 7" stove pipe and the Con-
tinental decorative brass band (standard with the
GS-150KT).  Both are available from your Continental
dealer.

Attach the B-Vent label, shown below, in the control area
of the appliance.

A chimney venting this stove shall not vent any solid fuel
burning appliance.

Any stove needs air for safe operation and must be in-
stalled in such a way that adequate combustion air is
available.

THREE TYPES OF
CHIMNEY SYSTEMS
MAY BE USED WITH
THIS STOVE:

FIGURES 29

FIGURE 31

Follow the instructions of the 'B' vent manufacturer for chim-
ney installation.

1.

Remove the access plate. Remove and discard the air

intake cover plate located directly behind the access plate.

2.

Feed the 2 wires, supplied, through the 7" collar at the

top of the unit; bring them out the air intake opening but
behind the rear panel as shown.

FIGURE 30

THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.

ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.

CE FOYER  A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.

B-VENT SPECIFICS - MODEL CS600

CHIMNEY INSTALLATION

COMBUSTION AIR

INSTALLING 'B' VENT:

B-VENT MODEL CS600 ONLY

Summary of Contents for CDCS600-P

Page 1: ...ller service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOU...

Page 2: ...he same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near...

Page 3: ...orkmanship and material for life subject to the following conditions During the first 10 years WOLF STEEL Ltd will replace or repair the defective parts at our option free of charge From 10 years to l...

Page 4: ...installation of a fireplace insert or gas log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installati...

Page 5: ...forsafeoperation Useafirestop when penetrating interior walls floor or ceiling Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the...

Page 6: ...ertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carboning U...

Page 7: ...7 W415 0162 E 03 05 04 FIGURE 8...

Page 8: ...ns and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10 ft...

Page 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Page 10: ...aulking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield sh...

Page 11: ...ent non combustible strapping to maintain the 1 clearance from combustibles FIGURE 23 FIGURE 24 This application occurs when venting through a roof Installation kits for vari ous roof pitches are avai...

Page 12: ...the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto th...

Page 13: ...cept a standard matte black 7 stove pipe and the Con tinental decorative brass band standard with the GS 150KT Both are available from your Continental dealer Attach the B Vent label shown below in th...

Page 14: ...r 1 2 type L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to the flex connec tor DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap...

Page 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Page 16: ...d at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermost...

Page 17: ...ill quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a norm...

Page 18: ...FF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all wi...

Page 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Page 20: ...ER 37 GD222 TERMINAL ASSEMBLY 38 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 39 W500 0077 FIRESTOP WALL PLATE 40 W020 0032 HARDWARE 41 BRTC7 BRASS TRIM COLLAR 42 BM6724 24 STOVE PIPE 7 DIAMETER 43 W010 030...

Page 21: ...21 W415 0162 E 03 05 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Page 22: ...ing no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper...

Page 23: ...free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or...

Page 24: ...24 W415 0162 E 03 05 04...

Reviews: