8.3 FLAME
CHARACTERISTICS
CBL36
GLASS MEDIA
It’s important to periodically perform a visual check
of the pilot and burner fl ames. Compare them to the
illustrations provided. If any fl ame appears abnormal
call a service person.
8.4
OPTIONAL
ANTI
CONDENSATION
SWITCH
This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for
cold climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using
your fi nger, fl ip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot fl ame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is fi rst turned on. It will also help
the fi replace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel
consumption.