FIGURE 3

Line the chimney with a 3" or 4" diameter approved liner. With 
a 4" liner, an increaser must be connected between the dilution 
draft hood and the liner. Chimney installation must conform to 
both national and local code requirements. The liner must be 
continuous from the fi replace to the chimney cap.

Remove the securing screw from the front of the dilution plate. 
Push the dilution draft hood out of the securing clips and at-
tach the liner using 3 screws equally spaced. Pack insulation 
around the liner at the damper area to prevent air fl ow from 
entering the chimney. Move the insert into the centre of the 
woodburning fi replace making sure that the dilution draft hood 
inserts back into its securing clips. Level using the four leveling 
screws located front and back on either side of the fi replace 
base. Leveling the insert will eliminate rocking or excessive 
noise when the fan is in operation. Replace the securing screw 
to the front of the dilution plate.

Install rigid black pipe, a fl ex connector, 

if local codes permit

or 1/2" type L, copper tubing with a 3/8" to 1/2" adapter and a 
shut off valve to the fi replace. Seal and tighten securely. The 
adapter will be required between the gas valve and the cop-
per tubing or fl ex connector. 

Do not kink fl exible connector!  

Check for gas leaks by brushing on a soap and water solution. 

Do not use open fl ame! 

INSTALLATION

FIGURE 1

Clean out ashes from the inside of the wood-burning fi replace. 
Make sure that the chimney and wood-burning fi replace 
are in a clean and sound condition and constructed of non-
combustible materials. If necessary have any repair work done 
by a qualifi ed person before installing the insert. Remove the 
existing fi replace damper or lock into an open position. 
Using screws, attach the fi replace warning tag  (W385-0199) 
to the inside of the fi rebox of the fi replace into which the insert 
is being installed.

The sheet-metal parts of the fi replace, in which the gas 
fi replace insert is to be installed, must not be cut.

If the wood-burning factory-built fi replace has no gas ac-
cess hole(s) provided, an access hole of 1½ inch or less 
may be drilled through the lower sides or bottom of the 
fi replace in a proper workman like manner. This access 
hole must be plugged with non-combustible insulation 
after the gas supply line has been installed.

Ensure that existing chimney cleanouts fi t properly.

The refractory, glass doors, screen rails, screen mesh 
and log grates may be removed from the fi replace before 
installing the gas fi replace insert.

Smoke shelves, shields and baffl es may be removed if 
attached by mechanical fasteners.

The ventilation openings in the fi replace may be  obstruct-
ed by the backer plates, aluminium trim etc. but these 
parts are not to be applied so as to have an airtight seal.

WARNING: 

THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE 

INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS 
ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY 
THE AUTHORITY HAVING JURISDICTION.

ATTENTION: 

CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME 

FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT 
AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE 
REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES 
AYANT JURIDICTION.

W385-0199

DILUTION DRAFT
HOOD

  DILUTION 

PLATE

SECURING 

CLIPS

FIGURE 2

27 

1

/

2

(30 

1

/

2

”)

43”

(49”)

30 

1

/

8

25”

18 

1

/

2

13 

1

/

2

1

/

2

3”

GAS INLET

17 

1

/

2

7”

ELECTRICAL INLET

LEFT SIDE

EXHAUST

(3"DIA)

8"

17 

1

/

4

22”

Summary of Contents for CBI 360-N

Page 1: ...mmediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perfor...

Page 2: ...r other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the co...

Page 3: ...material for life subject to the following conditions During the first 10 years CONTINEN TAL will replace or repair the defective parts at our option free of charge From 10 years to life CONTINENTAL...

Page 4: ...ing of the fireplace This insert must be recessed into a vented noncombustible woodburning fireplace prefabricated or masonry only The minimum fireplace size in which the heater is to be installed is...

Page 5: ...installing the insert Remove the existing fireplace damper or lock into an open position Using screws attach the fireplace warning tag W385 0199 to the inside of the firebox of the fireplace into whic...

Page 6: ...ded maximum lead length depends on wire size WIRE SIZE MAX LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve Do not connect the...

Page 7: ...ntered evenly above the pilot assembly 3 While supporting the back log to prevent it from fall ing forward set the three smaller logs into the pockets and grooves of the front and back logs respective...

Page 8: ...LE DEATH A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED INSERT IS LEFT WITH THE CUSTOMER Test after installing the unit into a vented non combustible fireplace in the following m...

Page 9: ...g the pilot with the push button ignitor Keep the knob fully depressed for one 1 minute then release If the pilot does not continue to burn repeat steps 3 through 7 9 With the pilot lit turn the gas k...

Page 10: ...up the back of the firebox and exhausted as hot air between the upper louvres Turn off the gas and electric power to the unit Remove the upper glass bracket Loosen the lower glass bracket and remove t...

Page 11: ...XE 6 PORCELAIN FLASHING KIT ALMOND 26 GI 909K6 DELUXE 6 PORCELAIN FLASHING KIT BLACK 26 GI 909F6 DELUXE 6 PORCELAIN FLASHING KIT GREEN FOR OPENINGS SMALLER THAN 30 X 48 26 GI 900B9 DELUXE 9 FLASHING K...

Page 12: ...12 W415 0120 F 10 25 11 20 12 9 15 26 39 38 16 14 1 2 5 6 4 3 21 13 10 11 27 33 34 37 35 36...

Page 13: ...he valve call the gas distributor turn on all gas appliances and see if pilot flame flutters di minishes or extinguishes especially when main burners ignite Monitor supply pressure check if supply pip...

Page 14: ...ney blockage check that chimney is installed to building code room is in negative pressure increase fresh air supply Fireplace is spilling reverse Remote wall switch is in off position main burner com...

Page 15: ...15 W415 0120 F 10 25 11 43 1...

Page 16: ...16 W415 0120 F 10 25 11 44 1 NOTES...

Reviews: