39
W415-1616 / C / 09.20.17
EN
5.2 MINIMUM ENCLOSURE CLEARANCES
TOP VENT
3" [76mm]
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK 0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76mm]
MINIMUM *
3" [76mm]
1 1/2"
[38 mm]
1"
[25mm]
50 1/2"
[1283mm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
15 7/8”
[40.3cm]
FIRESTOP
50 1/2”
[128.3cm]
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 50 1/2" (1283mm). For temperature
requirements, the enclosure space around and above the appliance must be left unobstructed.
* See "MINIMUM FRAMING DIMENSION" section for details on reducing vent pipe top clearances.
These perameters also apply to the illustrations found in the "MINIMUM ENCLOSURE
CLEARANCES" section.
NOTE:
The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
34 5/8"
[87.9cm]