5.3 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
BCDV33
CDV33
6” MINIMUM
1”
2”
20
1
/
4
”
MINIMUM
PLUS RISE *
2”
BRICK
COMBUSTIBLE
NON-COMBUSTIBLE
0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.
29”
The CDV33 requires a minimum enclosure
height of 35". For temperature requirements,
the enclosure space around and above the
appliance must be left unobstructed.
The BCDV33 requires a minimum enclosure
height of 33". For temperature requirements,
the enclosure space around and above the
appliance must be left unobstructed.
4” MINIMUM
2”
1”
2”
20
1
/
4
”
MINIMUM
PLUS RISE *
BRICK
COMBUSTIBLE
NON-COMBUSTIBLE
0” IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
29”
Combustible Mantel clearance can vary according to the Mantel depth. Use the graph
to help evaluate the clearance needed. These same requirements apply to any
combustibles protruding on either side of the appliance.
TOP OF
APPLIANCE
8" MANTEL
8" 6"
6"
4"
4"
2"
2"
5.4 MINIMUM MANTEL CLEARANCES
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
MANTEL DEPTH
M
A
N
T
E
L
H
E
,
*
H
T 0
2 4
6
8 10 12
2
4
6
8
10
12