5.9  FCC Information

This equipment has been tested and complies with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device 

may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.
The FCC limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, may cause harmful interfer-

ence to radio communications. However, there is no guarantee that interference will not occur in 

a particular installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is encouraged to 

try to correct the interference by one or more of the following measures:

 

Reorient or relocate the receiving antenna.

 

Increase the separation between the equipment and receiver.

 

Connect the equipment to a circuit different from that to which the receiver is connected.

 

Consult the dealer or an experienced radio/TV technician for help.

5.10 Warranty

All products sold by Continental Control Systems, LLC (CCS) are guaranteed against defects in 

material and workmanship for a period of five years from the original date of shipment. CCS’s 

responsibility is limited to repair, replacement, or refund, any of which may be selected by CCS at 

its sole discretion. CCS reserves the right to substitute functionally equivalent new or serviceable 

used parts.
This warranty covers only defects arising under normal use and does not include malfunctions or 

failures resulting from: misuse, neglect, improper application, improper installation, water damage, 

acts of nature, lightning, product modifications, alterations or repairs by anyone other than CCS.

Except as set forth herein, CCS makes no warranties, expressed or implied, and CCS dis-

claims and negates all other warranties, including without limitation, implied warranties of 

merchantability and fitness for a particular purpose.

5.11  Limitation of Liability

In no event shall CCS be liable for any indirect, special, incidental, punitive or consequen-

tial damages of any kind or nature arising out of the sale or use of its products whether 

such liability is asserted on the basis of contract, tort or otherwise, including without 

limitation, lost profits, even if CCS has been advised of the possibility of such damages.
Customer acknowledges that CCS’s aggregate liability to Customer relating to or arising 

out of the sale or use of CCS’s products, whether such liability is asserted on the basis of 

contract, tort or otherwise, shall not exceed the purchase price paid by Customer for the 

products in respect of which damages are claimed. Customer specifically acknowledges 

that CCS’s price for the products is based upon the limitations of CCS’s liability set forth 

herein.

©2009-2022 Continental Control Systems, LLC.

Document Number: WN-Inst-BN-2.31

Revision Date: April 4, 2022
Continental Control Systems, LLC

+1-303-444-7422, 

https://ctlsys.com

•  WattNode is a registered trademark of Continental Control Systems, LLC.
•  BACnet is a registered trademark of American Society of Heating, Refrigerat-

ing and Air-Conditioning Engineers (ASHRAE)

(M8)

Rev 2.31

Summary of Contents for WattNode BACnet RWNC-3D-240-BN

Page 1: ...anual WattNode BACnet Models WattNode Revenue for BACnet Models WNC 3Y 208 BN RWNC 3Y 208 BN WNC 3Y 400 BN RWNC 3Y 400 BN WNC 3Y 480 BN RWNC 3Y 480 BN WNC 3Y 600 BN RWNC 3Y 600 BN WNC 3D 240 BN RWNC 3...

Page 2: ...ct the Output Signals 9 3 6 Connect Thermistor 10 4 Operation 11 4 1 Initial Configuration 11 4 2 Power Status LEDs 11 4 3 Communication LED 12 4 4 Monitoring 12 4 5 Maintenance and Repair 12 5 Specif...

Page 3: ...Hazard from Dangerous High Voltage Functional ground should be connected to earth ground if possible but is not required for safety grounding UL Listing mark for U S A and Canada FCC Mark This logo i...

Page 4: ...neutral n a 166 276 3D 240 A and B 1 Phase 2 Wire 240V no neutral n a 166 276 3D 240 A and B 1 Phase 3 Wire 120V 240V with neutral 96 138 166 276 3Y 208 N and A 3D 240 A and B 3 Phase 3 Wire Delta 208...

Page 5: ...T L1 Neutral Earth 2 2 2 Single Phase Two Wire No Neutral This circuit occurs in residential commonly 120 240 Vac and some commercial applications The meter is powered from the A and B terminals We re...

Page 6: ...e phase delta service to be labeled as the C phase instead of the B phase The WattNode meter will work correctly with the high leg connected to A B or C See the web article https ctlsys com support fo...

Page 7: ...lled in an electrical service panel or an enclosure Do not use the meter as a drilling guide the drill chuck can damage the screw terminals and metal shavings may fall into the connectors The meter ha...

Page 8: ...onnect Current Transformers To meet the UL listing requirements the WattNode meter may only be used with UL Listed CTs with a 333 mVac output or the following UL Recognized current transformer models...

Page 9: ...pped the measured power will be negative The status LEDs indicate negative measured power by flashing red When installing WattNode Revenue models be sure to only use IEEE C57 13 class 0 6 current tran...

Page 10: ...tances and when using termination and biasing resistors If you have any questions consult the Operating and Reference Guide Be sure to connect the A B and C common terminals The X terminal is normally...

Page 11: ...eter displays the following startup sequence whenever power is first applied 1 0sec 1 0sec 1 0sec Green Yellow Red Green Yellow Red Green Yellow Red C B A 4 2 2 Positive Power Any phase with the LEDs...

Page 12: ...w Solid yellow indicates that this meter believes it is the sole master device on the network It will scan continuously for other devices until another device is found 4 4 Monitoring WattNode BACnet m...

Page 13: ...trical Meter Service Type Nominal Vac Line to Neutral Nominal Vac Line to Line Phases Wires 3Y 208 120 208 240 1 or 3 2 4 3Y 400 230 400 1 or 3 2 4 3Y 480 277 480 1 or 3 2 4 3Y 600 347 600 1 or 3 2 4...

Page 14: ...Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipment for industrial use an...

Page 15: ...onducted RF Immunity EN 61000 4 6 Voltage Dips Interrupts EN 61000 4 11 Emissions FCC Part 15 Class B EN 55022 1994 Class B 5 7 Environmental Operating Temperature 40 C to 75 C 40 F to 167 F Altitude...

Page 16: ...s the right to substitute functionally equivalent new or serviceable used parts This warranty covers only defects arising under normal use and does not include malfunctions or failures resulting from...

Reviews: