13 

2.4.12  Service group 
 
 
Example:                 
 
 
Programmation of the number of cycles when the machine will display: 
 
 
 
 
After this message the service has to be carried out by a technician. Then reset the machine in menu  
"SERVICE". 
 
The servicing has to be carried out after 12000 cycles – see chapter MAINTENANCE. 
 
 
2.4.13  Electrical Heating management 
 
Three-phase connection: The heating elements can be supplied simultaneously. 
Single-phase connection: the power supply has to be limited to 24, 19 or 14Ampers  
 
The display will show:   

 

 

 

Press + or – to change. 

 
Power 1: 

Consumption maxi: 14 A (230 V single-phase)   

 16 A Plug 

Power 2: 

Consumption maxi: 19 A (230 V single-phase) 

 20 A Plug 

Power 3: 

Consumption maxi: 24 A (230 V single-phase) 

 32 A Plug 

Power 4: 

TOTAL POWER (three-phase wiring only) 

 
 
2.4.14  Double click activation 
 
The double click activates a 2

nd

 function for each push-button. 

Double click:    

The delivered product is identical. 

  

The measurements are different (to be programmed). 

 

Usually used pour the same produits delivered double. 

 
2.4.15  Boiler filling 
 
To program the Steam boiler filling with or without pump
(in the case of the freestanding version, that requires the pump for the filling) 

without pump: Filling with water inlet solenoid valve;  
with pump

Filling with water inlet solenoid valve and pump. 

 
 

2.4.16  Drying time of the coffee grounds 
 
After delivery of the coffee, a pause generally programmed at 3 seconds will allow to eliminte the 
remaining pressure to avoid splashing of coffee grounds and dry the coffee grounds. 

Power 

1

 

Service group 

8995 

 cycles

 

SERVICE GROUP

 

Summary of Contents for TOUTAUTO 388

Page 1: ...01 2010 SACOME CONFIDENTIAL Document it is forbitten to duplicate or communicate this document without previous authorization PARAMETERS PROGRAMMING INSTRUCTIONS V 1 20...

Page 2: ......

Page 3: ...n the drawer 12 2 4 11 Water softener 12 2 4 12 Service group 13 2 4 13 Electrical Heating management 13 2 4 14 Double click activation 13 2 4 15 Boiler filling 13 2 4 16 Drying time of the coffee gro...

Page 4: ...6 Inferior Motor Expel Impulses 28 2 9 7 Inferior Motor Grinding position impulses 28 2 9 8 No Coffee Infusion Impulses 28 2 10 MENU Test Operating elements 29 2 11 MENU Service 30 2 11 1 General 30 2...

Page 5: ...the product parameters 1 2 Adjustement of the coffee temperature see Menu Parameter Adjust in chapter PROGRAMMING INSTRUCTIONS button to adjust the coffee temperature in the boiler ENTER button to va...

Page 6: ...nu access to TECHNICAL menu access to MANAGEMENT menu If the machine is in standby mode When inserting the appropriate chip card the programming mode will be entered automatically Example insert techn...

Page 7: ...c Beverage type Steam Beverage type Tea 3 Products Adjustments Tea Pump enabled Steam Double Disabled Tea Double Disabled Verify product Verify product Cappuccino Grind Time R 5 s Beverage type Coffee...

Page 8: ...Alarm History 1 Alarm 1 AA MM jj HH mm Total group cycle 44259 Right Grinder Time 30 H 22 min Water Softener 56 Left Grinder Time 30 H 22 min Payment type Coins Payment type Token 2 Alarm 2 AA MM jj...

Page 9: ...t up Encoder Test operat elements Filling up Service Data saving Reset Parameter ENTER ESC Smart Card manager Up date Software ON OFF ENTER ESC ENTER ESC ENTER ENTER ESC ENTER ESC ENTER ESC ENTER ESC...

Page 10: ...r T disabled Language French Language German ENTER ENTER Machine Combined Machine Cappuccino ENTER Switch On Automatic ENTER ESC See menu Automatic switch on ENTER ENTER T measure unit F ENTER or to c...

Page 11: ...Service group OFF Water softener 1 lit See menu Water softener Power 2 ENTER ENTER ENTER ENTER ENTER ENTER kP kI kD 3 8 0 04 10 0 or to change the coefficient of the PID regulator ENTER PID T regulat...

Page 12: ...the ON OFF button beneath the machine AUTOMATIC the machine will automatically switch on and off at programed hours 2 4 5 T Measure Setting of the temperature measure C or F 2 4 6 Adjusting of the T...

Page 13: ...T t Tc The electronic pilots the heating element according to The programmed T The actual T The progress speed of the actual T kP parameter Proportionel E t the T difference to correct to reach the Se...

Page 14: ...automatically If the parameter is set 0 The coffee grounds are not counted No alert in the case of a coffee grounds drain bin Maximum capacity of the drawer 45 coffee grounds 2 4 11 Water softener Wa...

Page 15: ...24 A 230 V single phase 32 A Plug Power 4 TOTAL POWER three phase wiring only 2 4 14 Double click activation The double click activates a 2 nd function for each push button Double click The delivered...

Page 16: ...cursor moves to the next field YY MM DD DAY HH MM 04 10 12 TUE 10 41 etc until coming back to the 1 menu level Date Hour Restaurant name Restaurant name Service phone Service name Service phone Servic...

Page 17: ...e Service phone Service name X ENTER The cursor blinks under the 1 field Choose the 1 number with et Press ENTER to validate The cursor moves to the next field The cursor blinks under the 1 field etc...

Page 18: ...e Service name Only the following messages are concerned by the calling of the maintenance ERROR DATA MINIMUM LEVEL FILLING UP T O COFFEE HEATER T O STEAM HEATER TIMEOUT MOTOR BOARD NO HIGH MOTOR IMP...

Page 19: ...ect button Beverage type coffee Beverage type tea ENTER ESC Press the button Beverage type Milk products ENTER ESC MODE Beverage type coffee milk ENTER ESC ESC ENTER ESC ENTER ESC ENTER ESC ENTER ESC...

Page 20: ...add value CC Name Preinfusion Ton 1 0 sec Name Number of cycles 1 Name Double click enabled or to adjust the time ON of the preinfusion in seconds or to adjust the time OFF of the preinfusion in seco...

Page 21: ...he grind 0 light 3 heavy or to adjust the water quantity value CC or to adjust the added water quantity value CC Decaf Preinfusion Toff 1 0 sec Decaf Number of cycles 1 or to adjust the time On of the...

Page 22: ...duct or to adjust the tea quantity value seconds Beverage type Steam ENTER ESC or to adjust the steam quantity Value seconds If the double click is enabled in Parameter adjustment the time has to be p...

Page 23: ...enabled in Parameter adjustment the time has to be adjusted for the second product Select name 2 Espressos Name Milk froth 5 0 sec or to adjust the milk froth quantity with air valve ENTER Select but...

Page 24: ...reinfusion value seconds or to adjust the number of cycles If the double click is enabled in Parameter adjustment the time has to be adjusted for the second product ENTER Select name 2 Espressos Name...

Page 25: ...s left grinder The group is carrying out a packing cycle No water is delivered to keep the grind dry The grind will be ejected Salvage the grind carefully and weigh it Adjust the grinders if the grind...

Page 26: ...eaning is not carried out THE MACHINE WILL BE JAMMED cleaning rinsing Auto rinsing group disabled Group cleaning alarm OFF Switch OFF cleaning disabled ENTER ESC ENTER or to adjust the number of cycle...

Page 27: ...le To programm the number of cycles of each rinsing 2 7 6 Time Out Auto Rinsing To prgramm the stand by time after the last coffee to start automatically the rinsing example After 30 minutes without c...

Page 28: ...coffee boiler to evacuate air in the coffee boiler Filling up Filling up Presser stop button ENTER When water flows from the outlet press the blinking button The pistons are put in place the infusion...

Page 29: ...the superior piston before stop 0 The piston is programmed in the factory to stop his stroke 20 increments before Z ro To avoid that the piston comes up against the stop No access to this menu with t...

Page 30: ...his menu with the technical card 2 9 6 Inferior Motor Expel Impulses To programm number of increments of the inferior piston to reach the ejection position The value is programmed at the factory at 53...

Page 31: ...Element EE 1 Test Operat Element VN 1 Test Operat Element VRT2 1 Test Operat Element VAP 1 Test Operat Element Cappu 1 Test Operat Element VC 1 Test Operat Element VRC 1 Test Operat Element AIR 1 Test...

Page 32: ...eset prod counter Total ENTER ESC Product counter Select button press button name 1x 46 2x 56 press button etc display of each counter of the each simple and double click buttons Return with ESC ENTER...

Page 33: ...ER ESC 1 Alarm1 AA MM JJ HH mm 2 Alarm2 AA MM JJ HH mm 3 Alarm3 AA MM JJ HH mm ESC ESC ESC ESC ESC Total groupe cycles 44259 Right grinder time 30 H 22 mn Service group Confirm reset ENTER ESC ENTER 2...

Page 34: ...gement Insert Smart Card ESC to MODIFY SYSTEM CODE Enter to confirm ENTER ESC ENTER ESC Create Bar Card Insert Smart Card ENTER ESC ENTER ESC Create technician card Insert Smart Card Create factory ca...

Page 35: ...eters Up date software ENTER ESC Machine card ENTER ESC Card Machine Insert CardDisk Swith off and on Insert CardDisk Remove Smart Card Remove Smart Card Switch off and on Preset parameters ENTER ESC...

Page 36: ...TE MACCHIATO LATTE MACCHIATO LATTE MACCHIATO LATTE MACCHIATO 2 LATTE MACCHIATO 2 LATTE MACCHIATO 2 LATTE MACCHIATO 2 LATTE MACCHIATO LAIT CHAUD HOT MILK HOT MILK LATTE CALDO 2 LAITS CHAUDS 2 HOT MILK...

Page 37: ...s 4 sec 2 products 4 5 sec 2 products 4 5 sec 2 products 5 8 sec 5 8 sec 4 5 sec 2 products 4 sec 2 products 4 Packing 3 3 2 0 0 0 0 0 2 5 Preinfusion On 1sec 1sec 0 sec 0 sec 0 sec 0 sec 0 sec 0 sec...

Page 38: ...roduct 30 cc 1 product 30 cc 1 product 60cc 1 product 7 Infusion 100 cc 2 products 100 cc 2 products 90 cc 2 products 90 cc 2 products 120 cc 2 products 60 cc 2 products 60 cc 2 products 120 cc 2 prod...

Page 39: ......

Page 40: ...e n u e Al b e r t I I B P 1 1 9 M C 9 8 0 0 7 M O N AC O C e d e x T l 3 7 7 9 3 1 0 4 3 4 3 F a x 3 7 7 9 3 1 0 4 3 4 4 h t t p w w w c o n t i e s p r e s s o c o m h t t p w w w c o n t i s p a r...

Reviews: