17 POWER MANAGEMENT
The Monte Carlo machines are three phase machines
When the machine is connected to a three-phase network, the absorbed power consumption does not need to be flanged.
In this case the Power Management is at its maximum position: 6.
The machine can be connected to a single phase 230V.
In this case:
1: Change the power cable with a cable 3x6 ² (Conti reference: 103600)
2: Depending on the available amperage on the grid (16A / 20A / 32A):
It is necessary to adjust the power consumption of the machine.
Through the Power management (see table below)
3: Here's how to connect the 3x6 ² cable on the general relay machine
Nota Bene:
It is possible to retain the original cable (5x2,5 ²), but in this case:
It is imperative to curb the power management 1 (or 2 maximum if the machine is not used too much)
Power parameters and Current comsumption (for 230 volts monophase)
Power 1
Power 2
Power 3
Power 4
Power 5
Power 6
Max power
(W)
Max current
(A)
Max power
(W)
Max current
(A)
Max power
(W)
Max current
(A)
Max power
(W)
Max
current
(A)
Max power
(W)
Max current
(A)
Max power
(W)
Max
current
(A)
MC 2G
1900
8
3300
14
4700
20
5700
25
6700
29
6700
29
MC 3G
2600
11
4600
20
6600
29
7600
33
8600
37
9600
42
MC 2G K
3000
13
5500
24
7500
33
9500
41
11500
50
11500
50
MC 3G K
3100
13
5600
24
8100
35
10100
44
12100
53
14100
61
Power 1/2/3/4/5/6:
That’s the number of heating element can be supplyied at the same time in the machine
The priority is always given to the coffee Boiler