Conti CG-200 OD Manual Download Page 9

 

Edition 11/2016 - CG200 OD 

SACOME, Document CONFIDENTIEL,

 Ne peut être reproduit ni communiqué sans notre accord préalable.

  

- 17 - 

 

B. 

Dose counting LCD: 

 

 

The CG200 OD model is equipped with 3 independent dosing counters. 

 

In order to view each one of the counters a single press on the counter selector will flip 
the LCD to the next counter and the relative counter’s LED will turn on. 

 

2 of the counters are resettable (middle and left most LED); in order to reset each of 
these 2 counters a 5 sec continues press on the counter selector will zero the 
relative counter. 

 

On single cup mode each coffee demand will increase the counting on all the 3 counters in 1 . 

 

On double cup mode each coffee demand will increase the counting on all 3 counters in 2. 

 

On continuous mode the counters are not counting. 
 
 

C. 

Programming grinding time for single and double cup modes: 

 

The CG200 OD is factory set with time values for single and double dose grinding periods. These 
pre set values are obviously estimated and user should find his own times according the coffee 
grinding request. In general as the coarseness of grind is coarser the time required to grind 
same weight of coffee is shorter.
 Additionally different type of coffee blends and coffee shops 
are requiring different dose size for their single and double cups: 

 6.5gr to 9.5gr per single cup 

 11gr to 18gr for double cup 

 
 

D. 

Grinding time setting: 

 

The CG200 OD is supporting the need of the user to change grinding time setting frequently. In order to 
change time setting of single cup or double cup mode please follow these steps: 

1.

 

Press the desired mode selector button continuously for longer than 3 sec. 
When in programming mode the mode selector’s LED is blinking. 

2.

 

Watch the LCD display is now showing your current set up time (in seconds and tents of 
seconds). 

3.

 

In order to increase or decrease set up time simply rotate the peripheral scale of the knob 
and watch the time set up on the LCD is changing up or down according direction of 
rotation. 

4.

 

When reaching the desired time value press shortly the mode selector button to return to 
normal working mode (watch the display is returning to counter mode).   

 
 

E. 

Adjusting coffee grind : 

 

The grinding blades’ distance was factory pre adjusted to satisfy different common coffee grinds (from 
super fine to coarse) corresponding gap distance from 0.05mm to 0.5mm. 

 Turning the grinding dial incrementally counterclockwise will make the grind finer  

 Turning it clockwise will make the grind coarser. 

Grind a small amount of coffee and test its coarseness with your espresso machine. 
As coffee beans’ qualities and characteristics are changing from time to time, it is recommended 
repeating this adjustment once in a while. 

 

 

 

 

Summary of Contents for CG-200 OD

Page 1: ...ACOME Document CONFIDENTIEL Ne peut tre reproduit ni communiqu sans notre accord pr alable SACOME CONFIDENTIAL Document it is forbidden to duplicate or communicate this document without previous autho...

Page 2: ......

Page 3: ...________________________________________ 14 4 UNPACKING AND INSTALLATION ___________________________________________ 15 5 OPERATION______________________________________________________________ 16 6 A...

Page 4: ...Edition 11 2016 CG200 OD SACOME Document CONFIDENTIEL Ne peut tre reproduit ni communiqu sans notre accord pr alable 12...

Page 5: ...rolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer wher...

Page 6: ...so machine filter holder Read this manual from cover to cover before using the appliance as it contains important instructions for the safety operation and maintenance of the appliance Keep the manual...

Page 7: ...letely through both holes in the hopper and in the top blade holder Fig 4 1 NEVER OPERATE THE GRINDER IF THE BEAN HOPPER IS NOT FULLY SECURED IN ITS POSITION Before plugging in the electrical cord mak...

Page 8: ...utton will start the grinder the relative LED will blink as long as the grinder is running stopping the grinder by another short press on continuous mode button Single cup mode while in single cup mod...

Page 9: ...rent dose size for their single and double cups 6 5gr to 9 5gr per single cup 11gr to 18gr for double cup D Grinding time setting The CG200 OD is supporting the need of the user to change grinding tim...

Page 10: ...SSORIES Filter holder support Fig 6 1 Fig 6 2 Fig 6 3 Fig 6 4 Notice the two holes under the filter fork support fig 6 1 Unpack the accessory fig 6 2 which is packed separately within the grinder pack...

Page 11: ...pliance B Grinding chamber safety screws The grinding chamber can be a hazardous area if the proper precautions aren t observed The hopper safety screw fig 4 1 and the grinding dial safety screw fig6...

Page 12: ...BRUSHES TO CLEAN THE APPLIANCE DO NOT USE ABRASIVE CLEANING PRODUCTS AS THEY MAY WEAR OUT THE APPLIANCE COATING A Cleaning the bean hopper Take off the bean hopper by releasing Bean Hopper safety scr...

Page 13: ...e residue off of the blades or the internal Teflon coating of the outlet port Examine both of the blades condition and replace them if necessary The replacement and assembly of a new set of blades is...

Page 14: ...e r t I I B P 1 1 9 M C 9 8 0 0 7 M O N AC O C ed e x T l 37 7 9 3 1 0 4 3 4 3 F a x 3 7 7 9 3 10 4 3 4 4 h ttp w w w co nt i es p r e s so co m ht tp w w w co nt i sp a r ep a rt s co m E m ai l te c...