Conti+ cont21300810274 Installation Manual Download Page 3

3

Conti Sanitärarmaturen GmbH, Hauptstraße 98, 35435 Wettenberg | Telefon: +49 641 98221 0 | Fax: +49 641 98221 50 | [email protected]
www.conti.plus | gültig ab 01/2018 | Artikelnummer CONDOK0030007 | Druckfehler und Irrtümer sowie technische und maßliche Änderungen vorbehalten

Important

BE SURE TO READ THE ATTACHED SAFETY 
INSTRUCTIONS BEFORE INSTALLING AND 
COMMISSIONING THE SYSTEM / PRO-
DUCT. 
INCORRECT INSTALLATION CAN CAUSE 
MALFUNCTIONS AND DAMAGE AND BE-
COME A DANGER FOR THE USER AND 
SPECIALIST CRAFTSMEN.
THE MANUFACTURER DOES NOT ASSUME 
ANY WARRANTY FOR IMPROPER OPERA-
TION AND IMPROPER USE.

Electrical wiring and installations must be car-
ried out by a qualified electrician in accordan-
ce with DIN VDE 105-100.
Only insert cables at specified positions. As-
sumption of warranty only if the specified ca-
ble types are used.
Observe VDE 100-701 when installing central 
control units.

| Install coin-operated machines in a 

  

  splash-proof vestibule
| Installation of control cabinets in drying   
  room 

At water temperatures above 45°C there is a 
risk of scalding!  

 

 

 

The worksheet DVGW W551 must be obser-
ved!
To avoid damage to functional components, 
malfunctions and water damage, comply with 
operating pressures in accordance with speci-
fied technical data.
Disconnect the water supply before assembly 
and disassembly of water-bearing compo-
nents and fittings.
Before and after installation, flush pipes in ac-
cordance with DIN EN 806-4 or ZVSHK leaflet 
"Flushing, disinfecting and commissioning of 
drinking water installations".

Store product in a frost-free, dry environment.
Check the fixing material in the scope of deli-
very  for  usability  for  current  wall  condition.                                                       
Only use stainless steel fixing screws.
Observe maintenance and repair obligations 
in accordance with VDI/DVGW 6023 or DIN 
EN 806-5.
Observe DIN 1988-200 or VDI/DVGW 6023 
when temporarily shutting down valves or 
other water-bearing components.
Do not insert or swallow small parts such as 
screws, seals or other metal or plastic parts 
into the body! This can lead to health dama-
ge, even life-threatening situations!
Before cleaning components, always read the 
instructions for use of the cleaning agent! 
Consult a qualified specialist before using the 
cleaner.
The use of CONTI+ spare parts from other 
manufacturers may result in damage to the 
component and will void the warranty imme-
diately.

IMPORTANT:
This product is subject to the 
provisions of the Electrical and 
Electronic Equipment Act in ac-
cordance with WEEE guidelines.

You can request the manufacturer's decla-
rations of conformity, test reports, technical 
certificates and further information from us. 
All documents are also available on our web-
site www.conti.plus

    

Summary of Contents for cont21300810274

Page 1: ...ung installation manual Warmlufttrockner warm air dryer H ndetrockner mit IR Sensor hand dryer with IR sensor passend f r suitable for CONT21500810272 wei white CONT21300810274 satin verchromt satin c...

Page 2: ...und Demontage was serf hrender Bauteile und Armaturenkompo nenten unterbrechen Vor und nach Montage Leitungen gem DIN EN 806 4 bzw ZVSHK Merkblatt Sp len Desinfizieren und Inbetriebnahme von Trink was...

Page 3: ...a Disconnect the water supply before assembly and disassembly of water bearing compo nents and fittings Before and after installation flush pipes in ac cordance with DIN EN 806 4 or ZVSHK leaflet Flus...

Page 4: ...50 60 Hz Class I Nennleistung nominal power 2400 W Heizleistung heating power 2200 W Motorleistung engine power 200 W Ger uschpegel noise level 70 dB A Max Luftstrom max air stream 96 l Sek 96 l sec...

Page 5: ...lasse I 230 V 50 60 Hz Class I Nennleistung nominal power 2400 W Heizleistung heating power 2200 W Motorleistung engine power 200 W Ger uschpegel noise level 70 dB A Max Luftstrom max air stream 96 l...

Page 6: ...30007 Druckfehler und Irrt mer sowie technische und ma liche nderungen vorbehalten Montage installation Warmlufttrockner warm air dryer technische Zeichnung technical drawing Hinweis Note Diese Abbild...

Page 7: ...eep observe wall material use suitable drills drill hole size suitable for dowels for 8mm screws 3 D bel im jeweiligen Bohrloch versenken Wandmaterial beachten geeignete D bel verwenden Anschlie end M...

Page 8: ...5 mm Empfohlene L nge 150 mm 7 mm abisoliert In the case of direct electrical connection with flush mounted cable or cable socket directly behind the device mounting plate the cable is routed through...

Page 9: ...hrzeigersinn Trocknungszeit verkleinern Drehung gegen den Uhrzeigersinn Der Trockner startet automatisch wenn die H nde in den Aktivierungsbereich gehalten werden und stoppt automatisch 2 Sekunden nac...

Page 10: ...rmittel und Padschw mme zu Sch den f hren kann Vorzugsweise Reinigungstextilien verwendet wer den die m glichst wenig Partikel binden k nnen Gewirkte T cher sind eher geeignet als gewebte Hinweis Auch...

Page 11: ...ts and pad spon ges may cause damage Preferably cleaning textiles are used which bind as few particles as possible Woven fabrics are more suitable than woven Tip Residues of body care products can als...

Page 12: ...Conti Sanit rarmaturen GmbH Hauptstra e 98 D 35435 Wettenberg Tel 49 641 98221 0 Fax 49 641 98221 50 info conti plus www conti plus...

Reviews: