1000W DMX smoke machine with HF remote control and Timer

English

6 - Preparation and maintenance

7 - Technical specifications

DMX Addressing

To be controlled via DMX devices, each unit needs its own DMX address so the remote control does not send 
information to untargeted units.
Your Smotec1000 only requires one channel.

Configure your dipswiches 1 to 9 in order for your units to receive the DMX signal. Please refer to the table below 
to learn about the matches between DMX addresses and the dipswitches binary code.

Dipswitches

#1

#2

#3

#4

#5

#6

#7

#8

#9

Decimal value

1

2

4

8

16

32

64

128

256

 

Example:

 

Address 1: Activate dipswitch #1 (value 1)
Address 9: Activate #1 and #4 ( value 1+8=9)

• Smoke output: 283m3 / minute
• Heater: 1000W
• Pre-heat time: 12 minutes
• Fluid tank: 2.8 litres
• Regular fluid consumption: 2.5 litres / hour at 100%

• Electronic management of fluid quantities
• Remote control: On /Off
• Remote control batteries : A27S DC 12V

• Remote control: Smoke projections duration and interval from 5 to 200 seconds
• DMX Channel : 1
• Power supply: 230V - 50Hz
• Power consumption: 1100W max.
• Dimensions: 468 x 250 x 148 mm
• Net weight: 11.4 kg

Preparation

• Fill the tank with smoke fluid. We strongly recommend to use the Contest

®

 

HD5L 

smoke fluid. It was designed 

to be used with the Smotec series and guarantees the best visual effects, with a very fast smoke dissipation.
• 

Your Smotec1000 and the HD5L fluid have been designed and optimised to be combined together. 

Using any other smoke fluid will void the warranty of your smoke machine.

• Connect the power cord of your smoke machine to an electrical outlet. If necessary, position the circuit-
breaker power switch on «On».
• Connect a DMX cable from a universal DMX remote control to use it in DMX.
• Please wait approximately 12 minutes for the heater to reach its operating temperature.

Storage and cleaning

• Once done with your Smotec1000, please unplug it and empty the tank.
• Pour a small amount of deionised water into the tank, plug the machine again and use it as if it was smoke 
fluid, until there is no water left in order to ensure an optimal lifespan.

Summary of Contents for Smotec 1000

Page 1: ...USER GUIDE 9576 December 2009 Version 1 0 1000W DMX smoke machine with HF remote control and Timer...

Page 2: ...this product or other property WARNING This unit contains no user serviceable parts Do not open the housing or attempt any maintenance by yourself In the unlikely even your unit may require service p...

Page 3: ...product away from any heat source such as a heaters amplifiers hot plates etc 10 Electric power supply This product can only be operated according to a very specific voltage These information are spe...

Page 4: ...motec1000 and its fluid canister The user guide you are currently reading A wireless remote control A wired remote control with Timer A Powercon cord In the event of one or several missing articles pl...

Page 5: ...after you turned on your device Note You must stay in a 50 m area around the machine for the receiver to maintain a proper connection with the remote control 5 DMX input 3 pin XLR socket allowing you...

Page 6: ...tion takes priority over the Timer function 5 Power On Off This button activates the remote control The LED will stop flashing and stay lit in green if information are received In order to use the sam...

Page 7: ...Smoke projections duration and interval from 5 to 200 seconds DMX Channel 1 Power supply 230V 50Hz Power consumption 1100W max Dimensions 468 x 250 x 148 mm Net weight 11 4 kg Preparation Fill the ta...

Page 8: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...

Reviews: