Contec PC-SDD32H User Manual Download Page 4

PC-SDD32H, 64H,

 

128H, 192H, 320H, 500H, 1000H

CONTEC CO., LTD.

- 4 -

Connector Pin Assignment

Pin

Signal

Function

I/O

Pin

Signal

Function

I/O

1

RESET-

Bus Reset

I

2

GND

Signal Ground

3

DB7

Data Bus Bit 7

I/O

4

DB8

Data Bus Bit 8

I/O

5

DB6

Data Bus Bit 6

I/O

6

DB9

Data Bus Bit 9

I/O

7

DB5

Data Bus Bit 5

I/O

8

DB10

Data Bus Bit 10

I/O

9

DB4

Data Bus Bit 4

I/O

10

DB11

Data Bus Bit 11

I/O

11

DB3

Data Bus Bit 3

I/O

12

DB12

Data Bus Bit 12

I/O

13

DB2

Data Bus Bit 2

I/O

14

DB13

Data Bus Bit 13

I/O

15

DB1

Data Bus Bit 1

I/O

16

DB14

Data Bus Bit 14

I/O

17

DB0

Data Bus Bit 0

I/O

18

DB15

Data Bus Bit 15

I/O

19

GND

Signal Ground

I/O

20

KEY

Key Pin

21

Open

22

GND

Signal Ground

23

IOW-

Host I/O Write

I

24

GND

Signal Ground

25

IOR-

Host I/O Read

I

26

GND

Signal Ground

27

IORDY

I/O ch RDY

O

28

Reserved

29

Reserved

O

30

GND

Signal Ground

31

INTRQ+ Interrupt Request

O

32

IOCS16-

Drive 16 Bit I/O

O

33

ADD1

Host Address 1

I

34

PDIAG-

Passed Diagnostic I/O

35

ADD0

Host Address 0

I

36

ADD2

Host Address 2

I

37

CSO-

Chip Select 0

I

38

CS1-

Chip Select 1

I

39

DASP-

Active (LED)

O

40

GND

+5V Return

41

+5V

+5VDC

42

+5V

+5VDC

43

GND

+5V Return

44

Reserved

Write Access Mean Time Before Failure

The PC-SDD H series accesses the same sector when overwriting a
file.    If a write error occurs, a substitute sector is used (290
substitute sectors are provided).

Accordingly, the mean time before failure for write access is the
time until all of the substitute sectors are used up.

The calculation formula is different depending on whether the size
of the file being written to is less than or greater than 32MB.

Summary of Contents for PC-SDD32H

Page 1: ...he product About the PC SDDxH This product is a silicon disk drive interchangeable with a 2 5 inch IDE hard disks This product provides exceptional robustness against environmental factors such as vib...

Page 2: ...limit on number of overwrites Rated voltage DC5V 5 Consumed power standby 85mW Typ idle 175mW Typ reading 275mW Max writing 300mW Max Operating conditions Temperature 0 60 C Humidity 8 95 with no cond...

Page 3: ...rs in NOMAL Mode Products Mode Size MB Cylinder Head Sector PC SDD32H NORMAL 32 489 4 32 PC SDD64H NORMAL 64 978 4 32 PC SDD128H NORMAL 128 978 8 32 PC SDD192H NORMAL 192 978 12 32 PC SDD320H NORMAL 3...

Page 4: ...e I 24 GND Signal Ground 25 IOR Host I O Read I 26 GND Signal Ground 27 IORDY I O ch RDY O 28 Reserved 29 Reserved O 30 GND Signal Ground 31 INTRQ Interrupt Request O 32 IOCS16 Drive 16 Bit I O O 33 A...

Page 5: ...No of accesses 10 834 313 Number of writes per hour Writes Hour 12 Once every 5 minutes Mean time before failure for write access Hours 10 834 313 12 902 859 103 years approx Example 2 All 40MB of a...

Page 6: ...LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC Co LTD CONTEC Co LTD makes no commitment to update or kee...

Page 7: ...applicable if the device has been tampered with or damaged through abuse mistreatment neglect or unreasonable use or if the original invoice is not included in which case repairs will be considered b...

Reviews: