Hardware Specifications

Format capacity
Bus specification

ATA (IDE-AT)

Transfer rate

ATA bus transfer rate

8.0Mbyte/sec(reading / writing)

Memory transfer rate 

(Reading)

5.0Mbyte/sec (reading)

(Writing)

0.71Mbyte/sec

1.5Mbyte/sec

2.5Mbyte/sec

3.0Mbyte/sec

3.0Mbyte/sec

3.0Mbyte/sec

3.0Mbyte/sec

Access rate 

(Reading) *1

2.0Mbyte/sec (reading)

(Writing) *1

0.5Mbyte/sec

1.0Mbyte/sec

1.3Mbyte/sec

1.5Mbyte/sec

1.5Mbyte/sec

1.5Mbyte/sec

1.5Mbyte/sec

Data reliability

Frequency of unrecoverable errors per bit:

Less than 1 / 10

14

 reads

ECC

64bits/Sector

Max. limit on number
 of  overwrites
Rated voltage

DC5V ± 5%

Consumed power

standby

85mW (Typ.)

idle   

175mW(Typ.)

reading 

275mW (Max.)

writing

300mW (Max.)

Operating conditions

Temperature

0~60

°

C

Humidity

8~95% (with no condensation)

Storage temperature

-20~80

°

C

Anti-vibration

15G Maximum (during operation)

Anti-shock

1000G Maximum (during operation)

External dimensions

69.85(W) x 100(D) x 12.5(H)mm

Weight

Approx. 100g

*1 An access rate is reference value.  Value may not correspond by the use condition.

Model

PC-SDD32H

PC-SDD64H

PC-SDD320H

Hardware Specifications

PC-SDD500H PC-SDD1000H

PC-SDD192H

PC-SDD128H

300,000 times per physical overwrites

1024MB

512MB

320MB

32MB

64MB

192MB

128MB

Note!

The number of times you can write to the silicon disk drive is
limited.
Avoid using it if you need to write the data frequently.

Summary of Contents for PC-SDD32H

Page 1: ...he product About the PC SDDxH This product is a silicon disk drive interchangeable with a 2 5 inch IDE hard disks This product provides exceptional robustness against environmental factors such as vib...

Page 2: ...limit on number of overwrites Rated voltage DC5V 5 Consumed power standby 85mW Typ idle 175mW Typ reading 275mW Max writing 300mW Max Operating conditions Temperature 0 60 C Humidity 8 95 with no cond...

Page 3: ...rs in NOMAL Mode Products Mode Size MB Cylinder Head Sector PC SDD32H NORMAL 32 489 4 32 PC SDD64H NORMAL 64 978 4 32 PC SDD128H NORMAL 128 978 8 32 PC SDD192H NORMAL 192 978 12 32 PC SDD320H NORMAL 3...

Page 4: ...e I 24 GND Signal Ground 25 IOR Host I O Read I 26 GND Signal Ground 27 IORDY I O ch RDY O 28 Reserved 29 Reserved O 30 GND Signal Ground 31 INTRQ Interrupt Request O 32 IOCS16 Drive 16 Bit I O O 33 A...

Page 5: ...No of accesses 10 834 313 Number of writes per hour Writes Hour 12 Once every 5 minutes Mean time before failure for write access Hours 10 834 313 12 902 859 103 years approx Example 2 All 40MB of a...

Page 6: ...LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC Co LTD CONTEC Co LTD makes no commitment to update or kee...