12
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacturer
manufacturer
manufacturer
manufacturer’’’’ssss declaration
declaration
declaration
declaration –
–
–
– electromagnetic
electromagnetic
electromagnetic
electromagnetic immunity
immunity
immunity
immunity –
–
–
–
for
for
for
for EQUIPMENT
EQUIPMENT
EQUIPMENT
EQUIPMENT and
and
and
and SYSTEMS
SYSTEMS
SYSTEMS
SYSTEMS that
that
that
that are
are
are
are not
not
not
not LIFE-SUPPORTING
LIFE-SUPPORTING
LIFE-SUPPORTING
LIFE-SUPPORTING
Guidance
Guidance
Guidance
Guidance and
and
and
and manufacture
manufacture
manufacture
manufacturerrrr’’’’ssss declaration
declaration
declaration
declaration –
–
–
– electromagnetic
electromagnetic
electromagnetic
electromagnetic immunity
immunity
immunity
immunity
The
CMS50QB
Pulse Oximeter
is intended for use in the electromagnetic environment specified below. The customer or the user of
CMS50QB
Pulse Oximeter
should assure that it is used in such an environment.
Immunity
Immunity
Immunity
Immunity test
test
test
test
IEC
IEC
IEC
IEC 60601
60601
60601
60601 test
test
test
test level
level
level
level
Compliance
Compliance
Compliance
Compliance
level
level
level
level
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic environment
environment
environment
environment ---- guidance
guidance
guidance
guidance
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to 2.5 GHz
3 V/m
Portable and mobile RF communications equipment should
be used no closer to any part of the
CMS50QB
Pulse
Oximeter
, including cables, than the recommended
separation distance calculated from the equation applicable
to the frequency of the transmitter.
Recommended
Recommended
Recommended
Recommended separation
separation
separation
separation distance
distance
distance
distance
P
V
d
⎥
⎦
⎤
⎢
⎣
⎡
=
1
5
.
3
P
E
d
⎥
⎦
⎤
⎢
⎣
⎡
=
1
5
.
3
80 MHz to 800 MHz
P
E
d
⎥
⎦
⎤
⎢
⎣
⎡
=
1
7
800 MHz to 2.5 GHz
Where
P
is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and
d
is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as determined
by an electromagnetic site survey,
a
should be less than the
compliance level in each frequency range.
b
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1
At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field
strength in the location in which the
CMS50QB
Pulse Oximeter
is used exceeds the applicable RF compliance level above, the
CMS50QB
Pulse Oximeter
should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the
CMS50QB
Pulse Oximeter
.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than
3 V/m.