4. Functions
(3) Click on the [Start Analyze] button. The analyzer utility analyzes the subsequent changes to lines.
When the communication you want to analyze has been completed, click on the [Stop Analyze]
button. The analysis results will be displayed on the screen.
Convenient usage
(1) Using the start and end triggers
During analysis, the analyzer utility can obtain data only when a specific condition is satisfied in
the entire session of communication. The condition that can be specified is a communication
status (polling, transmit/receive, etc.), a change to the control line (EOL, SRQ, ATN, etc.), a data
line match (specified ASCII code), or a delimiter match.
Select “Set Trigger Condition” from the “Set” menu.
The analyzer utility works as follows with the settings made on the Trigger Set Dialog below.
-
The analyzer utility starts analysis the moment IFC changes.
-
The analyzer utility ends analysis upon transmit/receive of data “CR” (0DH).