Step 5 Checking Operations with the Diagnosis
Program
Use the diagnosis program to check that the board and driver software work normally, thereby you can
confirm that they have been set up correctly.
What is the Diagnosis Program?
The diagnosis program diagnoses the states of the board and driver software.
It can also be used as a simple checker when an external device is actually connected.
Using the “Diagnosis Report” feature reports the driver settings, the presence or absence of the board,
I/O status, and interrupt status.
Check Method
Connect the board to a remote device to test the input/output and check the execution environment.
For this board, an external power supply is not required.
The Check Mate (CM-64L) comes in handy when you check digital I/O boards.
Check the board with the factor defaults untouched.
Connection diagram
CM-64L
GROUP 0
GROUP 2
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
GROUP 4
7 6 5 4 3 2 1 0
GROUP 6
7 6 5 4 3 2 1 0
GROUP 1
GROUP 3
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
GROUP 5
7 6 5 4 3 2 1 0
GROUP 7
7 6 5 4 3 2 1 0
ACK STB
CN3
POWER
Optional cable
PCB100/96PS-xx
Connector
Board
To connect a device other than the Check Mate, see Chapter 3 “External Connection”.