Digital filter settings
Set
Name
Meaning
Set item
Initial value
ST4 - 0
Digital filter setting
time
Set the digital filter
time
0: filter function not
used
0
[filter function not
used]
1:
0.25μsec
2:
0.5μsec
3:
1μsec
4:
2μsec
5:
4μsec
6:
8μsec
7:
16μsec
8:
32μsec
9:
64μsec
10:
128μsec
11:
256μsec
12:
512μsec
13: 1.024msec
14: 2.048msec
15: 4.096msec
16: 8.192msec
17: 16.384msec
18: 32.768msec
19: 65.536msec
20: 131.072msec
21 - 31: Reserve
Internal power ON/OFF setting port (Page 0h / Address 1Ch
–
1Dh)
R/W
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 PWEn
This ports sets enabled(ON) or disabled(OFF) of internal power for digital input port.
Read this port to check the setting status. See
Internal power ON/OFF setting (page 53)
”
for
setting value.
Internal power ON/OFF setting
Set
Name
Meaning
Set item
Initial value
PWEn
Internal power
enabled
Set the internal power enabled
(ON).
0: disabled (OFF)
1: enabled (ON)