Installation
—
CPS-MC341-ADSC1-111, CPS-MC341-ADSC2-111, CPS-MG341-ADSC1-111 Reference Manual (Hardware)
—
55
—
3.
Cable Connection
1.
Power
Power Cable
Use the power cable described below.
Cable
Twisted pair cable (when using a single wire, twist V+ wire and V- wire)
Cable
Diameter
AWG24 - 16(0.2mm
2
- 1.25mm
2
)
Cable Length
Within 3 meters
FG Cable
Use the FG cable described below.
Cable
Diameter
AWG18 - 16(0.75mm
2
- 1.25mm
2
)
Refer to
in the
page 24
for details of the power connector and pin assignment.
Specification of External Power Supply
This product is designed to operate at least with 15watt power supply.
In addition, the power supply must fulfill the following requirements.
Rising time
for up to 12
voltage
2 milliseconds up to 30 milliseconds
Cable
Use copper wires that tolerate a temperature of 75 °C or higher.
Recommended power supply is the optional product of the CPS-PWD-15AW12-01.
CAUTION
Removing the connector plug by grasping the cable can break the wire. Always grasp the
connector to remove it.
Tightening torque of the supplied connector is described below.
DEGSON : 0.19 N·m, PHOENIX CONTACT, PTR MESSTECHNIK : 0.25 N·m
Strip off approximately 7mm (plus or minus 0.5mm) of the covered part of a cable to connect
with the connector.