Product Nomenclature and Function
—
CPS-MC341-ADSC1-111, CPS-MC341-ADSC2-111, CPS-MG341-ADSC1-111 Reference Manual (Hardware)
—
36
—
Digital Filter Setting Time
Set the digital filter time to 0 – 20 (00h - 14h).
Setting the digital filter time to 0 disables the function of filtering (0 is set as default and upon turning
on the power).
Setting Data (n)
Digital Filter Time
Setting Data (n)
Digital Filter Time
0(00h)
Default setting
The filter function is
unused
11(0Bh)
256μsec
1(01h)
0.25μsec
12(0Ch)
512μsec
2(02h)
0.5μsec
13(0Dh)
1.024msec
3(03h)
1μsec
14(0Eh)
2.048msec
4(04h)
2μsec
15(0Fh)
4.096msec
5(05h)
4μsec
16(10h)
8.192msec
6(06h)
8μsec
17(11h)
16.384msec
7(07h)
16μsec
18(12h)
32.768msec
8(08h)
32μsec
19(13h)
65.536msec
9(09h)
64μsec
20(14h)
131.072msec
10(0Ah)
128μsec
-
-
The following lists the relation between digital filter time and setting data.
Digital Filter Time [sec] = 2
n
/(8x10
6
)
n: Setting Data (0 - 20)
CAUTION
The digital filter applies to all input channels; it cannot apply to only specific input pins.
To pass input signal without fail, the pulse width should be twice or larger than setting filter
time.
A digital filter doesnt work effectively if the filter time i s set (setting data: 1-10) shorter than
the opto-coupler response time.
The signal level remains the same over
the digital filter setting time, the digital filter
recognizes that signals as normal and
changes the filter output signal level.