5. Using the Memory Address Map
44
CNT16-8(FIT)GY,
CNT16-8L(FIT)GY
Items common to modules
- Module
startup
register
Setting the module startup option (01h) causes the device module to be started.
Setting the module startup option when the module is being started causes the module to be
restarted.
The CNT16-8x(FIT)GY does not contain a module shutdown function.
00h : No operation
01h : Module startup
- Error
status
The error status bits, which are not reflected in the module information area, always remain [00h].
The error status on a module is stored in the module information area.
- Counter
resolution
The counter resolution of the CNT16-8x(FIT)GY is 16 (10h) bit.
-
Digital filter setting
Sets the digital filter.
Table 5.2. Digital Filter Time and Setting Data
Setting Data
(n)
Digital
Filter Time
Setting Data
(n)
Digital
Filter Time
Setting Data
(n)
Digital
Filter Time
0 (00h) *1
Not used
7 (07h)
16
μ
Sec 14
(0Eh)
2.048mSec
1 (01h)
0.25
μ
Sec 8
(08h) 32
μ
Sec 15
(0Fh)
4.096mSec
2 (02h)
0.5
μ
Sec 9
(09h) 64
μ
Sec 16
(10h)
8.192mSec
3 (03h)
1
μ
Sec 10
(0Ah)
128
μ
Sec 17
(11h)
16.384mSec
4 (04h)
2
μ
Sec 11
(0Bh)
256
μ
Sec 18
(12h)
32.768mSec
5 (05h)
4
μ
Sec 12
(0Ch)
512
μ
Sec 19
(13h)
65.536mSec
6 (06h)
8
μ
Sec 13
(0Dh)
1024
μ
Sec 20
(14h)
131.072mSec
*1: Factory setting
CAUTION
- The default value for digital filter setting time is "Not used".
- Writing a setting data other than a "0" will apply this filter function to all input channels. This
function cannot be applied to particular pins only but is applied to all input channels.
- Do not set the setting data to any value other than the above. Doing so may result in a
malfunction.