2. System Reference
BX-956S User’s manual
11
Table 2.2. Installation Environment Requirements
Model
BX-956SD-DC7xxxxx
Ambient
specifications
Operating temperature
*4
(1) Horizontal installation : 0 - 50
°
C(With 1000BASE-T : 0 - 45
°
C)
(2) Vertical installation other than above : 0 - 45
°
C(With 1000BASE-T : 0 - 40
°
C)
Storage temperature
-10 - 60
°
C
Humidity
10 - 90%RH (No condensation)
Floating dust particles Not to be excessive
Corrosive gases
None
Line-noise
resistance
Line noise
AC line /
±
2kV *5,
Signal line /
±
1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Static
electricity
resistance
Contact discharge /
±
4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Atmospheric discharge /
±
8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
Vibration
resistance
Sweep
resistance
10 - 57Hz/semi-amplitude 0.375 mm 57 - 500Hz/5.0G
60 min. each in x, y, and z directions
(JIS C60068-2-6compliant, IEC68-2-6-compliant)
Impact resistance
100G, half-sine shock for 6 ms in x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Grounding
Class D grounding, SG-FG / continuity
Standard
VCCI Class A, FCC Class A,
CE Marking (EMC Directive Class A, RoHS Directive), UL/c-UL
*4 : For more details on this, please refer to chapter 3, “Installation Requirements”.
*5 : When AC adapter “ACAP19-01” is used.
Power Management Features
-
Support both ACPI (Advanced Configuration and Power Interface) .
-
ACPI v2.0 compliant
-
Hardware automatic wake-up