1. Before Using the Product
2
AO-1604LX-USB
- USB HUB function, the CONTEC’s USB supported products (Max. 4) can be used.
This product has the USB HUB
function. *2 Max. 4 AO-1604LX-
USB can be used in 1 USB port of
PC. When you use 4 or more AO-
1604LX-USB, you can do by
connecting AO-1604LX-USB to the
another USB port of PC side.
Also, you can connect the
CONTEC’s USB supported products
other than AO-1604LX-USB to the
USB port of AO-1604LX-USB.
*3*4
- Software-based calibration function
Calibration of analog output can be all performed by software. Apart from the adjustment information
prepared before shipment, additional adjustment information can be stored according to the use
environment.
- indows compatible driver libraries are attached.
Driver library API-USBP(WDM) that makes it possible to create applications of Windows is attached.
- Plug-ins for the dedicated libraries, this product also supports MATLAB and LabVIEW.
We offer a dedicated library [ML-DAQ], which allows you to use this product on MATLAB by The
MathWorks as well as another dedicated library [VI-DAQ], which allows you to use the product on
LabVIEW by National Instruments.
These dedicated libraries are available, free of charge (downloadable), on our web site.
*1 There are some differences of the specifications between this product and AO-1604L-LPE, DA16-
4L(LPCI)L. For more details on this, refer to “Chapter7, Difference from AO-1604L-LPE, DA16-
4(LPCI)L”
*2 This product cannot be stacked up for installation.
*3 Do not connect the device other than that of CONTEC’s USB to the USB port included on the AO-
1604LX-USB. Otherwise, this may cause a failure or malfunction.
*4 When connecting multiple units with USB HUB function and set up them, do one at a time and
complete setup for the previous unit before starting to do the next unit.
USB cable
USB cable
USB cable
USB cable