3. Setup
12
ADI16-4(USB)
Range Setting Switches
Inputs can be set as voltage or current inputs to suit your requirements. A single input range applies for
all channels and separate ranges cannot be set for each channel. Do not set other the specified settings.
Setup method
The voltage/current input setting is set using a DIP switch on the module's panel.
Set as shown below.
Figure 3.3 Input Range Setting
RANGE
RANGE
Voltage Input
(Factory setting)
Current Input