27
Note 1:
When adjusting the output current, if a level of 2.5 amps is reached
and yet
the field strength is still below -6dB,
the correct field
strength
will not
be achieved.
This is caused by either an incorrect loop design or installation, more
metal loss than expected or an incorrectly specified driver.
There is no need to go higher than +0dB ARMS.
Adjustment to drive current/level required based on the measured
field strength:
Measured Field
Strength
Output current that
will achieve 0dB
Steps to
increase Drive
Steps to
decrease Drive
6.00dB
1.00A
6
5.00dB
1.12A
5
4.00dB
1.26A
4
3.00dB
1.42A
3
2.00dB
1.59A
2
1.00dB
1.78A
1
.00dB
2.00A
0
0
-1.00dB
2.24A
1
-2.00dB
2.52A
2
-3.00dB
2.83A
3
-4.00dB
3.17A
4
-5.00dB
3.56A
5
-6.00dB
3.99A
6
-7.00dB
4.48A
7
-8.00dB
5.02A
8
-9.00dB
5.64A
9
-10.00dB
6.32A
10
-11.00dB
7.10A
11
-12.00dB
7.96A
12
-13.00dB
8.93A
13
-14.00dB
10.02A
14