Evaluation Kit User Manual
EV9000
2001 Consumer Microcircuits Limited
41
UM9000/2
Block #
Message #
1 2 3 4 5 6
1 0
0
0
0
3
0
2 0
1
0 0 0 0
3
0 0 0 0 0 0
4 0
1
0 0 0 0
Totals
0
2
0 0
3
0
Table 18: Test 6 Cumulative Block Result for One Message Type
Message structures are indicated in Table 19.
IC Type
Transmit Task Sequence
Receive Task Sequence
CMX909B
TSB, TDB
SFS with level and PLL acquire, RDB
CMX969,
FX919B
and
FX929B
T4S and T24S (pream. & frame sync), THB SFS with level and PLL acquire, RHB
T4S and T24S (pream. & frame sync), TIB
SFS with level and PLL acquire, RILB
T4S and T24S (pream. & frame sync), TLB SFS with level and PLL acquire, RILB
T4S and T24S (pream. & frame sync), all
TIB, except for the final block of TLB.
SFS with level and PLL acquire, all RILB
with CRC reported only for the final
block.
Table 19: Test 6 Message Structures
4.6.6.3 Screen Controls
There are no windows dedicated to this test. Press the HALT switch to abort this test.
4.6.6.4 Test Sequence
Because of its complexity, it is not practical to document the complete test sequence. Instead,
refer to the sequence documented in Test 5: "BER & DQ test 'B' to 'A' using unformatted data" for
a representative sequence of modem control.
4.6.6.5 Error Codes
Code Description
2
After writing RESET task to command register and waiting,
channel A or B modem did not produce a high BFREE status.
3
After writing LFSB task to command register and waiting,
channel A modem did not produce a high BFREE status.
9
Test aborted by pressing the HALT switch.
Table 20: Test 6 Error Codes