background image

 

2

 

 

SLTI 

Wireless 

Controller 

The SLTI controller can control an unlimited number of SL and RX heaters. The controller has 4 operating 
modes.  To activate the controller, press any button. The LCD screen will light up and the controller is ready 
to be used.   

Please read this guide carefully and retain for future use and maintenance purposes. 

Installation and User Guide 

 

BOOST mode (BOOST)   

  Heating aims for chosen target temperature for a set time before turning off. Once this time has been reached, 
  the controller will return to its previous operating mode.  
  Timer range is between 15 minutes and 4 hours
 

 

 

Manual mode (MAN) 
Heater maintains a chosen comfort temperature. 
Temperature range 15

°

C - 35

°

C.   

 

 

Setback mode (SETB) 
Heater can be set to standby, frost  protection or to maintain a setback temperature. 
Temperature range 4

°

C - 15

°

C, 4

°

C is frost protection and symbol  ‘- - -  is for stand by mode. 

 

 

7 Day program (PROG) 
7 day automatic timer mode 
Heater is operating on the preset Comfort and Setback periods. 
Up to 6 programmes per day. You can override preset programs to suit your requirements.  The steps for doing 
this are explained on the next page.  

Operating Modes

 

Overview

 

WARNINGS 

 

Do NOT handle the controller with wet hands. 

 

Do NOT use the controller in workshops or rooms with high dust     

exposure. 

 

Do NOT use the appliance if damaged. 

 

Do NOT leave the appliance unattended where young children 

are present. 

 

Ensure that nothing is pushed into any aperture of this controller. 

 

Operating temperature range -10 to +40ºC. 

Mode 

Temp 

Prog 

Time 

Press TIME to display 

current time 

Displays current room 

temperature 

Heater active symbol  

Displays which mode you 

are currently using 

Press TEMP to display 

current target          

temperature 

Press MODE to navigate 

between different     

operating modes 

Reviews: