7. Set 7-day programme 

06:00

 

10

 

20

 

08:00

 

19ºC

 

4ºC

 

ºC

 

12:00

 

22ºC

 

14:00

 

16:00

 

16ºC

 

22ºC

 

10ºC

 

22:00

 

PROGRAM 1

 

PROGRAM 2

 

PROGRAM

 3

 

PROGRAM

 4

 

PROGRAM 5

 

PROGRAM 6

 

An example of one day programme on PVE 

TIM

E S
ETT

IN

G

 

PROGR

A

M

M

E SET
TIN

G

 

-  SET  MINUTES 

-  SET  DAY 

-  SET  HOURS 

-  SELECT DAY  TO  SET  

-  SET  MINUTES  FOR  PROGRAM 

-  SELECT  PROGRAM  TO  SET 

-  SET  TEMPERATURE  FOR  PROGRAM 

Logic diagram for setting programme on PVE 

PROG 

-

 

1. 

Press and hold PROG for 5 seconds to enter the 
time setting. 

2. 

The day will be flashing.  

3. 

Use 

and 

-

 to navigate day, press PROG to 

select day.  

4. 

PROG 1 will be flashing. Use 

and 

-

 to navigate 

programme, use PROG to select programme. 

5. 

The minutes will be flashing. 

6. 

To set minutes, use 

and 

-

 to change minutes, 

press PROG to set the minutes. 

7. 

The hour will be flashing 

8. 

To set hour,  use 

and 

to change hour, press 

PROG to set the hour. 

9. 

The temperature will be flashing. 

10.  To set temperature, use 

and 

to change 

temperature, press PROG to set temperature. 

 

To add another programme repeat steps 2-10. 

The PVE has a 7-day timer with up to 6 programming 
steps available for each day. In the programming you 
can set a start time and a temperature for each 
program. This can be changed to a 5-day + 2-day 
timer, or a 24 hour timer in the settings menu. 
Instructions on doing this can be found in section 9. 

Set programme inactive. 

If you do not require the use of all 6 programs they can 
be set as inactive. When in programming mode select 
the programme you want to make inactive and press 
the TIME button. If the programs is inactive the display will 

show “

- -:- -

”. To activate the program again, press the 

TIME button. 

   

Copy day function. 

If you require the same set of programs throughout 
the week, hour timer is available. This will use the 
same program every day. A 5-day + 2-day timer is 
also available. This will use the same programs  
Monday-Friday, and the same programs Saturday 
and Sunday. These modes are enabled in the setup 
menu, as explained in section 9. 
 
Alternatively, it is possible to copy a program from 
one day to another.  
To do this, when programming the 7-day timer, press 
and hold the TIME button. This will bring you to the 
copy day mode. To select which day you wish to 
copy from, use the PROG button to cycle through 
numbers 1-7 on the screen, this relates to which day 
you would like to copy. 1=MON, 2=TUE, 3=WED etc. 
To select which day you would like to copy the pro-
grams to, use the 

to navigate to the day. Once 

both are selected, press the time button to copy the 
day. The TO should flash to confirm it has been suc-
cessful. 

-

 SET HOUR FOR PROGRAM

 

Summary of Contents for PVE050

Page 1: ...unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect yo...

Page 2: ...ce the appliance cools down Cleaning Always disconnect the heater from the mains before cleaning The heater should not require any maintenance but it is strongly advised that it is kept clean An occas...

Page 3: ...28 233 PVE075 750 428 233 PVE100 1000 568 303 PVE150 1500 703 497 PVE200 2000 768 582 3 Note The heater MUST be fully secured in the vertical position before being switched on It must be clicked into...

Page 4: ...d AUTO Pressing the MODE button whilst in the main menu will toggle between BOOST MANUAL and Auto mode 5 Manual Mode In Manual mode the heater maintains the set temperature To amend the set temperatur...

Page 5: ...n be changed to a 5 day 2 day timer or a 24 hour timer in the settings menu Instructions on doing this can be found in section 9 Set programme inactive If you do not require the use of all 6 programs...

Page 6: ...ds adjusting better accuracy required to suit different position in the room etc the reading can be recalibrated in 0 5 degree steps 02 change between degrees Celsius or Fahrenheit 03 set minimum temp...

Page 7: ...on Amendment EU Exit Regulations 2019 SI 2010 2617 The Restriction of use of Certain Hazardous Substances SI 2012 No 3032 The Waste Electrical and Electronic Equipment Regulations 2013 SI 2013 No 3113...

Reviews: