Consort PVE050 Installation & Control Manual Download Page 4

 

66001327 Iss 01 

Before you can use the PVE, it has to be activated by 
pressing any of the TIME, PROG, TEMP or MODE 
buttons once. The LCD backlight will turn on. To 
operate any control button, press within 2 seconds of 
activation. 
 
The PVE has a standby mode. Standby mode can be 
accessed by pressing the standby button. In this 
mode, the timer is locked and none of the control 
buttons will work. The heating is disabled. To exit 
standby mode, press the standby button. 
 
This mode can be used to provide frost protection. A 
minimum temperature can be set in the settings 
menu. Standby mode will always maintain this 

minimum temperature. ‘FROST PROTECTION’ will 

appear on the screen in standby mode when a 
minimum temperature is set. 
 
Information on setting the minimum temperature can 
be found in section 9. 

-

Press and hold the TIME button for 5 seconds. 

 

Minutes are flashing -  use 

and 

buttons to set 

 

minutes. 

-Press TIME button 

 

Hours are flashing -  use 

and 

buttons to set 

 

hours. 

-Press TIME button 
 

Day is flashing  -  use 

and 

buttons to set Day. 

 
Once set, press TIME to return to main screen. The PVE 
has a battery backup, so the time and day settings 
are saved in the event of power being lost. 

1. Basic Operation 

2. Time and day setting 

3. Selecting operating mode 

PVE has 3 operating modes: 
 

BOOST, MANUAL, and AUTO 
 

Pressing the MODE button whilst in the main menu will 
toggle between BOOST, MANUAL and Auto mode.  

5. Manual Mode 

In Manual mode, the heater maintains the set 
temperature. 
 
To amend the set temperature when in 

MANUAL 

mode, activate the display and then press TEMP. 
Next, use the 

+

 and 

-

 buttons to change the 

temperature. Once the temperature is set, you can 
leave the display to return to the main screen and the 
settings will be saved. 

4. Boost mode  

The boost feature increases the room temperature for 15 
minutes. 
 
To amend the set temperature when in 

BOOST 

mode, 

activate the display and then press TEMP. Next, use the 

+

 

and 

-

 buttons to change the temperature. Once the 

temperature is set, you can leave the display to return to 
the main screen and the settings will be saved. After 15 
minutes, the PVE will return to previous operating mode. 
 
Whilst in boost mode, activate the display and press the 

PROG button to increase the boost period. The boost 
period can be increased up to 4 hours. This will reset 
back to 15 minutes once you exit boost mode. 

In this mode, the PVE will follow the week’s time / 

temperature program. 

 

The temperature can be temporarily overridden in 

AUTO

 

mode by simply activating the display and using the 

+

 

and 

-

 buttons to set the new temperature. The new set 

temperature will be then maintained until the next 
program step. 
 
Advance mode can be used to advance to the next 
program. To do this, press PROG whilst in Auto mode. 
To clear advance mode, press PROG.

 

6. Auto mode  

Summary of Contents for PVE050

Page 1: ...unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect yo...

Page 2: ...ce the appliance cools down Cleaning Always disconnect the heater from the mains before cleaning The heater should not require any maintenance but it is strongly advised that it is kept clean An occas...

Page 3: ...28 233 PVE075 750 428 233 PVE100 1000 568 303 PVE150 1500 703 497 PVE200 2000 768 582 3 Note The heater MUST be fully secured in the vertical position before being switched on It must be clicked into...

Page 4: ...d AUTO Pressing the MODE button whilst in the main menu will toggle between BOOST MANUAL and Auto mode 5 Manual Mode In Manual mode the heater maintains the set temperature To amend the set temperatur...

Page 5: ...n be changed to a 5 day 2 day timer or a 24 hour timer in the settings menu Instructions on doing this can be found in section 9 Set programme inactive If you do not require the use of all 6 programs...

Page 6: ...ds adjusting better accuracy required to suit different position in the room etc the reading can be recalibrated in 0 5 degree steps 02 change between degrees Celsius or Fahrenheit 03 set minimum temp...

Page 7: ...on Amendment EU Exit Regulations 2019 SI 2010 2617 The Restriction of use of Certain Hazardous Substances SI 2012 No 3032 The Waste Electrical and Electronic Equipment Regulations 2013 SI 2013 No 3113...