Consort PLE050/SS Installation Manual Download Page 6

 

 

Ensuring you don’t waste energy on heating the outside 
world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically 
detect a temperature rise,  and switch itself back on. 
Once enabled in the setup menu, the open window 
detection is fully automatic and does not require any 
human intervention to be activated.   
 
Setting-up Open Window Detection 
The system has been factory set to default time and 
temperature values. If necessary, all values can be 
adjusted. When the heating is on, open window 
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2

°

C in less than 

10 minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2

°

C in less 

than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 

13. Open Window Detection 

66000852 Iss 02 

1. 

Press and hold TEMP and MODE together for 5 
seconds. 

2. 

The display will enter the setup menu. 

3. 

Use TEMP and MODE to change a value. 

4. 

Use  TIME to scroll between the settings. 

 

01 - temperature calibration 
The temperature reading has been factory calibrated 
but if for any reason it needs adjusting (better accuracy 
required, to suit different position in the room etc.), the 
reading can be recalibrated in 0.5 degrees steps. 

 

02 - change between degrees Celsius or Fahrenheit 

 

03 - set minimum temperature 

 

       (3.5 deg = frost protection) 

 

When this is set, the heater will operate in any mode 
should the room temperature fall below the set 
temperature.

 

 

04 - set maximum temperature 

 

When this is set, the maximum temperature in any mode 
cannot exceed the limit. 
 
05 - open window detection  0 = off, 1 = on 

 

06 - 600 - open window detection time 600 seconds 

 

07 - 2 - temperature drop of 2

°

C in the detection time 

 

08 - 30 - closed window detection time of 30 seconds 

 

09 - 2 -

 

temperature rise of 2

°

C in the detection time 

14. Setup menu 

Locking tab 

Locking screw 

15. Optional PLK1 Locking Device 

- Locking screw 

- Locking tab 

The PLK1 locking device can be used to mechanically 
lock the controls to prevent tampering with settings. As it 
is not supplied with the heater, kindly contact our Sales 
team if required. 

16.  Mounting 

To wall mount, the wall bracket supplied must be used.  

Please refer to illustrations in Fig.1. 
 
Remove wall bracket from the heater.  Fix wall bracket to 
wall using screw holes provided.  Present heater to 
bracket.  Locate heater onto bottom lugs via 2 sets of 
relevant slots in rear panel.  Hinge heater upwards and 
locate the top tabs into the slots in the back of the 
heater and ‘click’ into position. 
 
To remove the heater from the wall first disconnect the 

power then press down on the two top tabs to release 
the heater.  Hinge the heater forward on the bottom 
lugs.  The heater can be now lifted off the bottom lugs to 
remove it from the wall.  The heater must not be located 
immediately below a fixed socket outlet. 
 

 