background image

 

 

40000061 Iss 01 

Important—please read 

 

The silica sheath of the heating elements should not 
be touched by hand, otherwise permanent marks 
(devitrification) will occur during heating.  WHEN 
ASSEMBLING HOLD THE ELEMENTS BY THE CERAMIC 
BUSHES AND OBSERVE THE CLEANING INSTRUCTIONS 
AFTERWARDS. 

 

Overview 

 
Please read this guide carefully and retain for future 
use and maintenance. 
 
This appliance has been designed and 
manufactured to the highest international 
standards, however, care must be taken for optimal 
results and safety. This appliance also meets the 
requirements of EU Directive 2004/106/EC for EMC 
and 2009/125/EC Directive. 
 

Safety & Care 

 
The appliance is not intended for use by persons 
(including children) with reduced physical, sensory 
or mental capabilities or lack of experience and 
knowledge unless they have been given supervision 
or instruction concerning use of the appliance by a 
person responsible for their safety.  
 

Warning 

 

 

Do NOT site the appliance into a corner. 

 

Do NOT use the appliance in workshops or rooms 
where excessive dust is generated or present. 

 

Do NOT touch outlet grille when the appliance is 
in use. 

 

Do NOT cover or restrict any aperture of the 
appliance when in use. 

 

Do NOT use the appliance if damaged. 

 

Do NOT leave the appliance unattended. 
 
 

Cleaning 

 

Always disconnect the heater from the mains before 

cleaning.  The heater should not require any 
maintenance, but it is strongly advised that it is kept 
clean.  An occasional wipe over with a soft cloth is 
all that should be necessary. 

 

Do NOT use metal or furniture polish on any part 
of the heater. 

 

Do NOT touch the heater with wet hands or in 
any way bring water into contact with it. 

If the supply cord is damaged, it must be replaced 
by the manufacturer or its service agent or a similarly 
qualified person in order to avoid a hazard. 

If Your Heater Does Not Work 

 

 

Check that power is available to the heater.  The LED 
light on the SL receiver should be illuminated 

 

Check that the fuse in the spur unit has not blown. This 
can be done by replacing the fuse with another 
suitable fuse. 

 

Check if the heater is paired with the SL controller 

 
Should none of the above remedies work, then telephone 
the helpline number shown in these instructions (UK ONLY). 
Do not attempt to repair the heater. 

 

Connection to the Main Supply 

 

Electrical installation should be carried out by a 
competent installer, preferably registered with NICEIC in 
accordance with the 17 edition of the IEE Wiring 
Regulations, (BS.7671), and any relevant Local Authority 
Bye-Laws. This heater is fitted with a 3-core mains supply 
cable and should be permanently connected to the 
electricity supply via a double pole switch having 3mm 
gap on each pole. A switched Fused Connection unit to 
BS.1363. Part 4 is a recommended mains supply 
connection accessory to ensure compliance with safety 
requirements applicable to fixed-wiring installation. 
Note:  When  switched  on  for  the  first  time  the  appliance 
may emit a slight smell.   
WARNING:  
This appliance must be earthed. 
When refitting the lid care must be taken to align the light 
pipe on the lid with the indicator light.

 

 

 
 
 
 
 

 

 

 

 
 
Assembly

 

The  Twin-Zone  heater  is  designed  to  provide  widespread 
warmth  (broad  beam)  or  a  more  concentrated  beam  of 
heat  over  a  localised  area  (narrow  beam),  and  the 
selection of either is made by adjusting the position of the 
element.   This is determined by ensuring that the ceramic 
blocks  supporting  the  silica  tubing  are  mounted  into  the 
heater body in the correct position.  Long end of ceramic 
blocks  downwards  will  give  narrow  beam  and  short  end 
downwards will give broad beam.  (See Fig 2).

 



INDICATOR 