Consort CN2MLSTiERF Installation & Control Manual Download Page 6

 

 

Ensuring you don’t waste energy on heating the outside 

world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically 
detect a temperature rise and switch itself back on. 
Once enabled in the setup menu, the open window 
detection is fully automatic and does not require any 
human intervention to be activated.  

 

Setting-up Open Window Detection 

The system has been factory set to default time and 
temperature values. If necessary, all values can be 
adjusted. When the heating is on, open window 
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2°C in less than 10 
minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2°C in less 
than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 

15. Open Window Detection 

1. 

Press and hold TEMP and MODE together for 5 
seconds. 

2. 

The display will enter the setup menu. 

3. 

Use TEMP and MODE to change a value. 

4. 

Use  TIME to scroll between the settings. 

 
01 - temperature calibration 
The temperature reading has been factory calibrated 
but if for any reason it needs adjusting (better accuracy 
required, to suit different position in the room etc.), the 
reading can be recalibrated in 0.5 degree steps. 

 
02 - change between degrees Celsius or Fahrenheit 
 
03 - set minimum temperature

 

 

       (3.5 deg = frost protection) 

When this is set, the heater will operate in any mode 
should the room temperature fall below the set 
temperature.

 

 
04 - set maximum temperature 

When this is set, the maximum temperature in any mode 
cannot exceed the limit. 

 
05 - open window detection  0 = off, 1 = on 
 
06 - 600 - open window detection time 600 seconds 
 
07 - 2 - temperature drop of 2

°

C in the detection time 

 
08 - 30 - closed window detection time of 30 seconds 
 
09 - 2 -

 

temperature rise of 2

°

C in the detection time 

16. Setup menu 

18. Intelligent Fan Control 

The intelligent fan control incorporates one of the latest 
low energy consumption BLDC motors. This allows the 
heater to operate quietly, whilst still providing the best 
possible levels of comfort.  

 

Depending on which heat mode is activated, it will 

calculate the best possible airflow temperature and will 
adjust the fan speed accordingly.  
 
If the heater is   running in fan mode only (heat switched 
off), then the fan will operate at a fixed speed. 

 

19. Mounting 

This unit is for wall mounting only.  

It is designed to be 

very quiet in operation if mounted correctly. When fitting 
more than one heater into a room we would recom-
mend that they are sited on the same wall to  
optimise airflow and ensure quiet operation.

 

 
M

OUNTING

 

ON

 

A

 P

LASTERBOARD

 W

ALL

 

  Where the heater is fitted onto plasterboard only, 

 

ensure plasterboard fixings are used.  Standard wall 

 

plugs will not be suitable. 

  Where possible mount the heater(s) on an outside 

 

wall to inhibit transfer of sound within the building.

 

NB: 

Failure to follow the instructions and  

recommendations provided could result in increased 
noise levels. 

 
To wall mount follow the below steps; 
1. 

 Mark screw fixing positions on the wall in accord-
ance with dimensions shown on Fig.1 on page 3.  

2. 

Drill 4 holes for  8mm wall plugs. 

3. 

Insert plugs in to the holes. 

4. 

The two keyhole screws can be now screwed in 
until the heads are approximately 2mm from the 
wall. 

5. 

Position the appliance on the partially inserted 
wall screws 

6. 

Secure wall brackets to the wall 

17. Status light on the heater

 

   Light colour                                   Heater status 

STAND-BY  No heat output 

Reduced heat output 

Full power heat output 

14. Keys locking 

Press and hold TIME and TEMP together for 5 seconds. The  

display will show        symbol.  Repeat the step to unlock.     

Summary of Contents for CN2MLSTiERF

Page 1: ...o an unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorized by us This guarantee is offered to you as an extra benefit and does not affe...

Page 2: ...e unit is switched off and then back on but the LED will flash red continuously Thermally Operated Cut Out The appliance is fitted with a thermally operated cut out TOC In the unlikely event that the...

Page 3: ...tach screws to the wall following the recommended clearances in figure 1 Remove the two wall brackets that are screwed to the bottom of the heater Rotate them 180 degrees as shown in figure 1 Install...

Page 4: ...ode and then use the PROG button to increase the timer in 15 minute increments After it reaches 4 hours and PROG is pressed again the timer resets to 15 minutes To amend the set temperature when in BO...

Page 5: ...u can set a start time and a temperature for each program 13 Heat symbol on the display Every time there is a demand for heat the display will show the heat icon Reduced heat output when the room temp...

Page 6: ...open window detection 0 off 1 on 06 600 open window detection time 600 seconds 07 2 temperature drop of 2 C in the detection time 08 30 closed window detection time of 30 seconds 09 2 temperature ris...

Page 7: ...ed it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard 21 Connection to the Main Supply Electrical installation should be carried out b...