Consort CN2MLSTiERF Installation & Control Manual Download Page 5

 

 

66001141 Iss 01 

9. Set 7-day Program 

06:00

 

10

 

20

 

08:00

 

19ºC

 

4ºC

 

ºC

 

12:00

 

22ºC

 

14:00

 

16:00

 

16ºC

 

22ºC

 

10ºC

 

22:00

 

PROGRAM 1

 

PROGRAM 2

 

PROGRAM

 3

 

PROGRAM

 4

 

PROGRAM 5

 

PROGRAM 6

 

An example of one day program on 

CN2MLSTiERF

 

TIM

E S
ETT

IN

G

 

PROGR

A

M

 S

ET

TIN

G

 

-  SET  MINUTES 

-  SET  DAY 

-  SET  HOURS 

-  SELECT DAY  TO  SET PROGRAM 

-  SET  MINUTES  FOR  PROGRAM 

-  SELECT  PROGRAM  TO  SET 

-  SET  TEMPERATURE  FOR  PROGRAM 

Logic diagram for setting program on CN2MLSTiERF 

PROG 

MODE 

TEMP 

1. 

Press and hold PROG for 5 seconds to enter the 
time setting. 

2. 

The day will be flashing.  

3. 

Use TEMP and MODE to navigate day, press PROG 
to select day.  

4. 

PROG 1 will be flashing. Use TEMP and MODE to 
navigate program, use PROG to select program. 

5. 

The minutes will be flashing. 

6. 

To set minutes, use TEMP and MODE to change 
minutes, press PROG to set the minutes. 

7. 

The hour will be flashing 

8. 

To set hour,  use TEMP and MODE to change hour, 
press PROG to set the hour. 

9. 

The temperature will be flashing. 

10.  To set temperature, use TEMP and MODE to 

change temperature, press PROG to set 
temperature. 

 

To add another program repeat steps 2-10. 

The CN2MLSTiERF has a 7-day timer with up to 6 
programming steps available for each day. In the 
programming you can set a start time and a 
temperature for each program.  

13. Heat symbol on the display 

Every time there is a demand for heat, the display will 
show the heat icon. 

 

     -     Reduced heat output when the room  temperature 
is close to the set temperature -  allows for almost silent 
operation. 

 

       -   full heat output 

11. Advance mode 

Press PROG from PROG mode to bring forward the next  
program. To clear advance mode, press PROG. 

If you do not require the use of all 6 programs they should 
be set as inactive. When in programming mode select 
the program you want to make inactive and press the 
TIME button. If the program is inactive the display will show 

- -:- -

”. To activate the program again press the TIME 

button. 

If you require the same set of programs throughout 
the week it is possible to copy all the programs from 
one day to another.  
To do this, when in programming mode press and 
hold the TIME button and this will bring you to the 
copy day mode. To select which day you wish to 
copy press the PROG button and this will cycle 
through numbers 1-7 on the screen, this relates to 
which day you would like to copy. 1=MON, 2=TUE, 
3=WED etc. 
To select which day you would like to copy the pro-
grams to, use the TEMP & MODE to navigate to the 
day. Once both are selected, press the time button 

to copy the day. The ‘To’ will flash to indicate this has 

been done. 

-

 SET HOUR FOR PROGRAM

 

12. Copy day function 

10. Set program inactive  

Summary of Contents for CN2MLSTiERF

Page 1: ...o an unsuitable electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorized by us This guarantee is offered to you as an extra benefit and does not affe...

Page 2: ...e unit is switched off and then back on but the LED will flash red continuously Thermally Operated Cut Out The appliance is fitted with a thermally operated cut out TOC In the unlikely event that the...

Page 3: ...tach screws to the wall following the recommended clearances in figure 1 Remove the two wall brackets that are screwed to the bottom of the heater Rotate them 180 degrees as shown in figure 1 Install...

Page 4: ...ode and then use the PROG button to increase the timer in 15 minute increments After it reaches 4 hours and PROG is pressed again the timer resets to 15 minutes To amend the set temperature when in BO...

Page 5: ...u can set a start time and a temperature for each program 13 Heat symbol on the display Every time there is a demand for heat the display will show the heat icon Reduced heat output when the room temp...

Page 6: ...open window detection 0 off 1 on 06 600 open window detection time 600 seconds 07 2 temperature drop of 2 C in the detection time 08 30 closed window detection time of 30 seconds 09 2 temperature ris...

Page 7: ...ed it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard 21 Connection to the Main Supply Electrical installation should be carried out b...

Reviews: