4. „On-Off Toggle“ Switch (Activation and Break Time can be set independently)
While the button at the input „SET“ is kept pushed, the relay is activated or deactivated according to the respective switch-on time (T1) and break
time (T2) set, starting with the activation time T1.
Releasing the button at the input „SET“ cancels the function.
The push of a button at the input „RESET“ deactivates the relay output immediately.
5. „On-Off Toggle“ with Setting Repetitions (Activation and Break Time can be set independently)
If the button at the input „SET“ is pushed, a positive level is pending and the relay is activated at once. The relay is activated or deactivated
according to the respective switch-on time (T1) and break time (T2) set, starting with the activation time T1.
The number of repetitions can be set by PC software (maximum number of repetitions = 255).
If the button at the input „SET“ is pushed while the function is already running, this has no effect on the relay output.
The push of a button at the input „RESET“ deactivates the relay output immediately.