7.  Press the “UP” button repeatedly until the desired weekday setting (weekday or weekday combination) 

is displayed. The weekday settings are displayed in the following order: 

 

MO → TU → WE → TH → FR → SA → SU 
→ MO TU WE TH FR → SA SU → MO TU WE TH FR SA 
→ MO WE FR → TU TH SA → MO TU WE → TH FR SA 
→ MO TU WE TH FR SA SU

8.  Press the “PROG” button to confirm your selection and to set the off time for the first program. The 

display will show “OFF” (off). Set the turn-off time according to the instructions provided in steps 2 to 8.

9.  Press the “PROG” button to program additional turn-on and turn-off times, or press the “OK” button to 

select the clock time mode. If you want to program additional turn-on and turn-off times, proceed as 

described in steps 2 to 9.

10. In clock time mode, press the “SET” button to select “AUTO”, “OFF” or “ON” mode. The modes are 

displayed in the following order. 

 

AUTO (Power switched on. Timer activated)
→ OFF (Power switched off. Timer deactivated)
→ ON (Power switched on. Timer deactivated) 

11. In order to delete a program, press the “PROG” button repeatedly until the desired program is displayed. 

You have to delete each turn-on and turn-off time separately. Press the “CLEAR” button to delete the 

selected program. The program will be deleted immediately without any confirmation prompt.

c) Random function

If the random function is activated it has priority over programmed turn-on and turn-off times. It is not 

necessary to program a period during which the random function will activate. The random function will 

activate several times randomly between 18:00 and 6:00 o’clock for a maximum ON/OFF cycle of one hour. 
Press the “SET” button to select “AUTO” mode. Simultaneously press the “SET” and “UP” buttons to activate 

or deactivate the random function. The display will show “RANDOM” indicating the random function being 

activated.

 

d) Countdown function

This function is intended for a device to turn on or off after a certain time has elapsed. The countdown 

function is only available in “ON” and “OFF” modes. In “ON” mode, the power will switch off after the set time 

has elapsed. In “OFF” mode, the power will switch on after the set time has elapsed. Set the time to elapse 

until switching on or off the power as follows:
1.  Connect a device and switch it on. 
2.  Simultaneously press the “PROG” and “UP” buttons to program the countdown function. The display will 

show “COUNTDOWN”. Set the time between 1 minute up to 99 hours and 59 minutes.

3.  Press the “SET” button. The ► symbol in front of “HOURS” starts flashing. 
4.  Press the “UP” button repeatedly until the desired hours are displayed. Press and hold the “UP” button to 

quickly scan through the hours. Use this procedure to set the “MINUTES” next.

5.  Press the “SET” button. The ► symbol in front of “MINUTES” starts flashing.
6.  Press the “UP” button repeatedly until the desired minutes are displayed.
7.  Press the “OK” button to start the countdown. “COUNTDOWN” starts flashing and the set time starts 

counting backwards in the display.

8.  After the set countdown has elapsed, the device will turn on or off depending on the respective operating 

mode.

9.  Simultaneously press the “PROG” and “UP” buttons to deactivate the countdown function.

e) Resetting the device

In case of malfunctions, if the display does not work properly or if pressing a button does not cause any 

response of the device, press the red “RESET” button. In order to do so, use an object with a round tip or 

the end of a paper clip. All stored data will be reset. You will have to set the clock time and any programmed 

times again. 

If the rechargeable battery is not completely discharged and still contains a small amount of 

power, the display will not turn on. Connect the timer to a wall socket (230 V/AC, 50 Hz) and 

press the “RESET” button to reset the device and to activate the display.
If the built-in battery is completely discharged, connect the timer to a wall socket. The display 

will turn on immediately.

Maintenance and cleaning

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they 

can cause damage to the housing and malfunctioning.

•  Unplug the timer from the wall socket before cleaning.
•  Never submerge the product in water or other liquids.
•  There are no user-serviceable parts inside the product. Never open/dismantle the product.
•  To clean the product, a dry, soft and clean cloth is sufficient. Do not apply too much pressure to the housing 

to prevent scratching.

•  You can easily remove dust using a long-haired, soft and clean brush.

Disposal

a) Product

Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.
The built-in battery must be disposed of by a specialist.

b) (Rechargeable) batteries

You as the end user are required by law (Battery Ordinance) to return all used batteries/rechargeable 

batteries. Disposing of them in the household waste is prohibited.

Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal 

in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = 

Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash 

icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores 

or wherever (rechargeable) batteries are sold. 

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage ............................. 230 V/AC, 50 Hz
Backup battery .................................. 1 x 2.4 V, 40 mAh NiMH rechargeable battery
Switching power ............................... max. 3680 W
Switching current .............................. max. 16 A
Standby power consumption ............ 0.45 W 
Programs .......................................... 16 turn-on and turn-off programs
Setting time ....................................... min. 1 minute, max. 7 days
Time display ..................................... 24 or 12 hours
Storage/operating temperature ......... 0 to 50° C 
Dimensions (W x H x D) ................... 73 x 145 x 80 mm
Weight .............................................. 202 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau 

(www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, 

or the capture in electronic data processing systems require the prior written approval by the editor. 

Reprinting, also in part, is prohibited. This publication represent the technical status at the time of 

printing.

© Copyright 2016 by Conrad Electronic SE. 

V3_0416_02-HK

Reviews: