Use in accordance with manufacturer’s instructions
The light is intended for use outdoors (protection type IP68) and it may also be used in or under water (e.g.
to illuminate a pond, swimming pool or suchlike).
Any other use than that described above may damage the product. Moreover, this may give rise to hazards
such as short-circuiting,
fi
re, electric shock, etc. No part of the product may be modi
fi
ed or converted!
The safety instructions must be observed at all times!
This product complies with the applicable National and European requirements. All names of companies and
products are the trademarks of the respective owner. All rights reserved.
Package Contents
• Light
• Triangular Base Mount
• Operating Instructions
Explanation of Symbols, Inscriptions
This symbol indicates a health hazard, e.g. electric shock.
The exclamation mark indicates speci
fi
c risks associated with handling, function and use.
IP68
Protection Type IP68, product suitable for operation in or under water (max. depth 5m)
The product complies with protection class III.
Safety Instructions
Read the complete operating manual carefully before using the product, as it contains
important information about the correct installation and operation.
The warranty will be void in the event of damage caused by failure to observe these safety
instructions! We do not assume any liability for any consequential damage!
Nor do we assume any liability for material and personal damage caused by improper use
or non-compliance with the safety instructions! In such cases, the warranty will be void!
• The unauthorised conversion and/or modi
fi
cation of the product is inadmissible because of
safety and approval reasons (CE).
• The product is not a toy and should be kept out of the reach of children!
• The product must be operated only on a suitable transformer with an output voltage of 12V
AC. Never try to operate the product at another voltage as this will cause its destruction.
• The device is designed according to protection class III.
• The product is protected according to IP68. It is intended for use outdoors, where it can also
be operated in or under water.
• The product must not be exposed to extreme temperatures, strong vibrations or heavy me-
chanical stress.
• Do not use this product in rooms or under adverse ambient conditions where combustible
gases, vapours or dust are or may be present! There is a risk of explosion!
• The product may only be used when it is installed in a stationary location.
• Attention, LED light:
Do not look directly into the LED light!
Do not look into the beam directly or with optical instruments!
• If you have reason to assume that safe operation is no longer possible, disconnect the product
immediately and secure it against accidental operation. Let an expert check the product.
A safe operation can no longer be assumed, if:
- the product shows visible signs of damage,
- the product does not work at all or well (
fl
ickering light, leaking smoke or a smell of burning,
audible cracking noises, discolouration to the product or the adjacent surfaces.)
- the device was stored for a longer period of time in unfavourable conditions
- it was exposed to heavy loads during transport
•
Do not leave packing materials unattended. They may become dangerous playthings for children.
• In commercial institutions, the accident prevention regulations of the employer’s liability insur-
ance association for electrical systems and operating facilities are to be observed!
Preparations for Installation
• The product is suitable for use in unprotected areas outdoors; it may also be operated in or under water
(protection type IP68).
The maximum water depth for operating the light is 5 m.
The length of the connection cable is about 4.5 m. In order to bene
fi
t from the maximum water
depth, or to lay the cable over long distances underwater, the connecting plug requires the
appropriate type of protection.
The light’s connecting plug as well as the actual socket on the transformer, or the terminal block,
required for operation are not waterproofed for use in or under water! Protect them from water
intrusion, e.g. with a suitable housing or similar.
• The product is only intended for use in freshwater. Protect the light from salt water (e.g. de-icing salt in the
winter) since this may cause corrosion.
• Only install the light on a stable surface.
• Place the connecting cable so nobody can trip over it. The connecting cable must not be driven over by
vehicles; moreover, do not step on the cable!
This can damage the connecting cable (short-circuit or break), which will destroy not only the light, but
possibly the transformer that is used for operation as well.
• The light and the connecting cable are only intended for use in stationary locations.
• The transformer used to power the light must be protected on the distribution board, provided by the user,
by a 10/16A fuse. Please consult the operating instructions for the transformer.
• During installation and connection of the light, the power must be disconnected. Switch off the transformer
used to supply the power, or unplug its mains plug from the mains socket.
Installation/Connection
Read the information in chapter “Preparations for Installation” prior to installation and
connection!
• A triangular mounting plate is included in this package. The light is placed in this bracket in such a way that
the cable lies in the opening of the bracket. Then place the bracket on the ground (e.g. in a pond, etc.).
• Connect the plug on the end of the light’s connecting cable to the corresponding socket on your trans-
former (output voltage 12V AC). For the data for the light, please see the chapter “Technical Data”. The
polarity is not important for the connection.
Maintenance and Care
The light does not require maintenance. Never dismantle the product.
Prior to cleaning, the light must be switched off; allow it to cool down suf
fi
ciently.
The outside of the light should only be cleaned with a soft, clean cloth. Where it becomes very dirty, use a
cloth which is slightly moistened with lukewarm water. Do not press on the protective glass too hard; this
may cause scratches.
Do not use aggressive cleaning agents or chemical solvents to clean the light under any circumstances.
Disposal
Dispose of an unserviceable product in accordance with the relevant statutory regulations.
Technical Data
Operating voltage ..........................................12 V/AC
Power consumption .......................................max. 2.4 W
Protection class .............................................III
Protection type ...............................................IP68
Light source ...................................................1x LED (1W), not replaceable
Colour temperature ........................................3000 - 3200K, warm white
Cable type .....................................................H05RN, 2 x 0.75 qmm
Cable length ................................................approx. 4.5 m
Water depth for operation of the light ............max. 5 m
Dimensions (Ø x h): .......................................48 x 28 mm (without bracket)
Weight ...........................................................approx. 485 g (with connecting cable, without bracket)
O P E R A T I N G I N S T R U C T I O N S www.conrad.com
LED Underwater Light, IP68
Item no. 57 81 78
Version 04/11
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, micro
fi
lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.