background image

3.3V and 5V Levels:

There is a 3.3V level (TxD) at pin X2. If your application requires a TTL level (5V), you need
to connect pin X2 to pin X1. Then you can get the TTL level from pin X4 (TxD_5V).

When the TTL driver is not required, connect pin X1 to GND!

The RxD pin X3 can always process signals between 3V and 5V. It is not dependent on the
TxD driver wiring!

When connecting a USB connection cable, make sure that the cable connections
are established correctly. In case of polarity reversal, not only the converter is
destroyed but also the corresponding USB port. Loss of warranty/guarantee!

Software Installation

First install the enclosed driver software!
Then connect the converter to the USB port.

Technical data

Supply voltage: ................................................. +5V/DC via USB
Power input depending on baud rate: ............. Max. approx. 100mA
TTL-TxD level: .................................................. Between 4.5V and USB-Vcc
Permissible ambient temperature: ................... 0°C to +60°C
Permissible relative moisture: .......................... 20 to 80%, non-condensing
Dimensions: ...................................................... approx. 18 x 16 x 15mm

Disposal

Dispose of the product at the end of its service life in accordance with the current
statutory requirements; e. g. return it to any suitable collecting point.

Mini-USB to UART Converter

Item no. 19 73 26

Intended Use

This product serves to connect a device with a UART interface to a USB port (USB1.1 or
USB2.0). The converter can convert interfaces with a TTL level (5V) and 3.3Volt level to USB.
The converter circuit board is welded directly or through a socket rail e.g. to a conductor plate
or contacted via a socket rail (grid size 2.54 mm).
This product complies with the applicable national and European specifications. All company
names and product names are trademarks of their respective owners. All rights reserved.

Scope of Delivery

• Mini-USB to UART Converter
• CD with driver
• Operating instructions

Safety Notices

The guarantee/warranty will be void if damage is incurred resulting from
non-compliance with the operating instructions. We will not assume any
responsibility for consequential damage!
Nor do we assume liability for damage to property or personal injury
caused by improper use or failure to observe the safety instructions. In
such cases the warranty/guarantee is voided.

• For safety reasons, any unauthorized conversion and/or modifications to the product are

not permitted.

• The product is not a toy and must be kept out of the reach of children.
• The product must not become damp or wet. It is approved only for operation in dry rooms.
• Do not leave packaging material lying around carelessly. It might become a dangerous toy

for children!

Pin assignment

Pin Number

Description

X1

TTL Driver input (connect to GND when not used!)

X2

TxD 3.3Volt

X3

RxD

X4

TxD 5Volt TTL

X5

GND

X6

VBUS USB-Power 5Volt/ 100mA

Signal Level 3.3V

Signal Level 5V TTL

Version 11/09

These operating instructions are a publication by Conrad Electronic SE, Klaus-
Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment
reserved.

© Copyright 2009 by Conrad Electronic SE.

O P E R A T I N G  I N S T R U C T I O N S

www.conrad.com

Summary of Contents for 19 73 26

Page 1: ...hsenleisten Rastermaß 2 54mm kontaktiert Dieses Produkt erfüllt die gesetzlichen nationalen und europäischen Anforderungen Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber Alle Rechte vorbehalten Lieferumfang Mini USB zu UART Konverter CD mit Treiber Bedienungsanleitung Sicherheitshinweise Bei Schäden die durch Nichtbeachten dieser Bedienungsanleitung ...

Page 2: ...European specifications All company names and product names are trademarks of their respective owners All rights reserved Scope of Delivery Mini USB to UART Converter CD with driver Operating instructions Safety Notices The guarantee warranty will be void if damage is incurred resulting from non compliance with the operating instructions We will not assume any responsibility for consequential dama...

Page 3: ... VBUS USB Power Output 5Volt 100mA Niveau de signal 3 3 V Niveau de signal 5 V TTL Version 11 09 Niveaux 3 3 V et 5 V Un niveau 3 3 V TxD est disponible sur la broche X2 Si vous avez besoin d un niveau TTL 5 V pour vos applications vous devez relier la broche X2 avec la broche X1 Vous pouvez alors mesurer le niveau TTL sur la broche X4 TxD_5V Si le pilote TTL n est pas utilisé la broche X1 doit êt...

Page 4: ...pegel 3 3V Signaalpegel 5V TTL Versie 11 09 3 3V en 5V pegel Aan pin X2 staat een 3 3V pegel TxD ter beschikking Wanneer u voor uw toepassing een TTL pegel 5V nodig heeft moet u pin X2 met pin X1 verbinden Daarna kunt u aan pin X4 TxD_5V de TTL pegel vastzetten Als de TTL driver niet nodig is dan moet pin X1 met GND worden verbonden De RxD pin X3 kan altjd signalen tussen 3V en 5V verwerken Dit is...

Reviews: