Input Impedance
To select an input load impedance other than the factory preset 47
kohms unplug the Premier Fifteen, and remove the cover. The input
impedance of the Premier Fifteen is set by the load selector switches -
the two dual inline pin (dip) switch arrays located near the input connec-
tors at the back of the unit. Each dip array includes four switches labeled
1 through 4. Load impedances are selected as follows:
impedance switch #
1 2 3 4
47 kohms o o o o
9.6 kohms x o o o
1.9 kohms o x o o
500 ohms o o x o
200 ohms o o o x
x indicates switch in "on" position
o indicates switch in "off" position (indicated by arrow on switch)
Be sure to set both switches. Replace cover.
Do not operate the unit
with the cover off.
The factory preset 47K load (all switches off) will be best suited to most
cartridges.
Premier Fifteen Owner’s Manual
6