![Conrad-johnson design PREMIER 15 Owner'S Manual Download Page 6](http://html1.mh-extra.com/html/conrad-johnson-design/premier-15/premier-15_owners-manual_2654933006.webp)
stances of EMI problems which could be treated locally as needed,
rather than compromising the performance of our product in the 99.9%
of installations where EMI is not a problem.
Care in installation can often avoid EMI induced problems. The following
practices should generally be observed in any application, and will be
especially important where EMI may be a problem.
Interconnect cables should be kept as short as possible (3 meters or
less), and shielded cable should be used (cable which has two center
conductors, and a separate external shield connected at only one end).
Physical location and cable "dress" can be an important factor in
minimizing hum pickup. The installation should situate the preamplifier
well away from the power amplifier, and power (ac mains) cords should
be dressed to remain at least 4" (100mm) away from input/output
cables.
Connection
Input:
Connect your tonearm leads to these inputs. The load presented
to the cartridge is determined by the internal load switch. See explana-
tion below.
Output:
Connect the outputs to any line level input on your preamplifier.
Premier Fifteen Owner’s Manual
5
Summary of Contents for PREMIER 15
Page 1: ......