Chapter 4
Installing the Drive
Page 28
Filepro CFP4207 Series
Installing a CFP4207E
The following paragraphs describe the installation procedure for a 16-bit wide
data transfer, Single Connector Attachment (SCA) interface, model CFP4207E
drive.
Setting the Drive's Jumpers - CFP4207E
There are no jumpers to set on the model CFP4207E and CFP1007E drives since
all the necessary control signals are on the SCA connector. This drive is
intended for applications where the drive is configured at the interface when the
drive is plugged into the interface connector.
Setting the SCSI Bus Address - CFP4207E
The SCSI bus ID of the drive is set by grounding the Interface bus signals shown
below in Table 4-4.
Table 4-4
Setting the SCSI ID
SCSI ID
SCSI ID(0)
SCSI ID(1)
SCSI ID(2)
SCSI ID(3)
0
Open
Open
Open
Open
1
Ground
Open
Open
Open
2
Open
Ground
Open
Open
3
Ground
Ground
Open
Open
4
Open
Open
Ground
Open
5
Ground
Open
Ground
Open
6
Open
Ground
Ground
Open
7
Ground
Ground
Ground
Open
8
Open
Open
Open
Ground
9
Ground
Open
Open
Ground
10
Open
Ground
Open
Ground
11
Ground
Ground
Open
Ground
12
Open
Open
Ground
Ground
13
Ground
Open
Ground
Ground
14
Open
Ground
Ground
Ground
15
Ground
Ground
Ground
Ground