
Installing the Drive
Chapter 4
Technical Reference Manual
Page 33
Setting the SCSI Bus Address - CFP2105S
There are three jumpers available for configuration of the SCSI ID: E1, E2, and
E3.
An optional 2mm pin pitch right angle header is located on the front of the
PCBA (opposite the SCSI interface connector) which allows changing the SCSI
IDs while the drive is mounted in the system. The header includes three pins,
0E1, 0E2 and 0E3 which can alternatively be used to select the SCSI Bus
address. This connector may also be used to cable the SCSI ID select to a remote
switch. A receptacle connector Amp P/N 111622-1 or equivalent can be used to
connect a ribbon cable to this header.
Table 4-6 defines the relationship between the jumpers and the SCSI ID:
Table 4-7
Setting the SCSI ID
Optional header
0E1
0E2
0E3
Standard
E1
E2
E3
SCSI ID
Out
Out
Out
0
In
Out
Out
1
Out
In
Out
2
In
In
Out
3
Out
Out
In
4
In
Out
In
5
Out
In
In
6
In
In
In
7
Note: When controlling the SCSI ID remotely, In = Ground or TTL
Low and Out = Open or TTL High. The odd numbered pins (lower
row) are grounded and the even numbered pins carry the signal.
Summary of Contents for CFP2105 series
Page 2: ......
Page 16: ...Chapter 1 Overview of the Drives Page 8 Filepro CFP2105 Series...
Page 28: ...Chapter 2 Specifications Page 20 Filepro CFP2105 Series...
Page 60: ...Chapter 4 Installing the Drive Page 52 Filepro CFP2105 Series...
Page 79: ...SCSI Physical Characteristics Chapter 5 Technical Reference Manual Page 71...
Page 80: ......