Appendix 1. Downlink messages table

Interval / 
min

Active Power Control On

Active Power Control Off

10 8000000000000000 C000000000000000
15 8001000000000000 C001000000000000
20 8002000000000000 C002000000000000
25 8003000000000000 C003000000000000
30 8004000000000000 C004000000000000
35 8005000000000000 C005000000000000
40 8006000000000000 C006000000000000
45 8007000000000000 C007000000000000
50 8008000000000000 C008000000000000
55 8009000000000000 C009000000000000
60 800A000000000000 C00A00000000000

0

65 800B000000000000 C00B00000000000

0

70 800C000000000000 C00C00000000000

0

75 800D000000000000 C00D00000000000

0

80 800E000000000000 C00E000000000000
85 800F000000000000 C00F000000000000
90 8010000000000000 C010000000000000
95 8011000000000000 C011000000000000

100 8012000000000000 C012000000000000
105 8013000000000000 C013000000000000
110 8014000000000000 C014000000000000
115 8015000000000000 C015000000000000
120 8016000000000000 C016000000000000
125 8017000000000000 C017000000000000
130 8018000000000000 C018000000000000
135 8019000000000000 C019000000000000
140 801A000000000000 C01A00000000000

0

145 801B000000000000 C01B00000000000

0

150 801C000000000000 C01C00000000000

0

155 801D000000000000 C01D00000000000

0

160 801E000000000000 C01E000000000000
165 801F000000000000 C01F000000000000
170 8020000000000000 C020000000000000
175 8021000000000000 C021000000000000
180 8022000000000000 C022000000000000
185 8023000000000000 C023000000000000
190 8024000000000000 C024000000000000
195 8025000000000000 C025000000000000
200 8026000000000000 C026000000000000
205 8027000000000000 C027000000000000
210 8028000000000000 C028000000000000
215 8029000000000000 C029000000000000

220 802A000000000000 C02A00000000000

0

225 802B000000000000 C02B00000000000

0

230 802C000000000000 C02C00000000000

0

235 802D000000000000 C02D00000000000

0

240 802E000000000000 C02E000000000000
245 802F000000000000 C02F000000000000
250 8030000000000000 C030000000000000
255 8031000000000000 C031000000000000
260 8032000000000000 C032000000000000
265 8033000000000000 C033000000000000
270 8034000000000000 C034000000000000
275 8035000000000000 C035000000000000
280 8036000000000000 C036000000000000
285 8037000000000000 C037000000000000
290 8038000000000000 C038000000000000
295 8039000000000000 C039000000000000
300 803A000000000000 C03A00000000000

0

305 803B000000000000 C03B00000000000

0

310 803C000000000000 C03C00000000000

0

315 803D000000000000 C03D00000000000

0

320 803E000000000000 C03E000000000000
325 803F000000000000 C03F000000000000
330 8040000000000000 C040000000000000
335 8041000000000000 C041000000000000
340 8042000000000000 C042000000000000
345 8043000000000000 C043000000000000
350 8044000000000000 C044000000000000
355 8045000000000000 C045000000000000
360 8046000000000000 C046000000000000
365 8047000000000000 C047000000000000
370 8048000000000000 C048000000000000
375 8049000000000000 C049000000000000
380 804A000000000000 C04A00000000000

0

385 804B000000000000 C04B00000000000

0

390 804C000000000000 C04C00000000000

0

395 804D000000000000 C04D00000000000

0

400 804E000000000000 C04E000000000000
405 804F000000000000 C04F000000000000
410 8050000000000000 C050000000000000
415 8051000000000000 C051000000000000
420 8052000000000000 C052000000000000
425 8053000000000000 C053000000000000
430 8054000000000000 C054000000000000

Summary of Contents for PressGuard R4.1

Page 1: ...PressGuard R4 1 User manual ...

Page 2: ...ing this manual 3 Read me first 3 PressGuard 4 Assembling and Installation 5 Uplink 7 Downlink 8 Downlink Payload description 9 Troubleshooting 10 Technical specifications 11 Appendix 1 Downlink messages table 12 ...

Page 3: ...www connectedinventions com for the latest version of the manual Available features and additional services may vary by service provider Applications on this device may perform differently from comparable applications and may not include all functions available by ie downlink messaging features Connected Inventions is not liable for performance issues caused by third party applications or improper...

Page 4: ...oor air in a building The device measures and sends the pressure difference data once in every 30 minutes by default thus the interval can be configured remotely with downlink message Connected PressGuard uses worldwide Sigfox IoT network for data transmission enabling very low lifetime cost and long battery life up to five years Versatile connected maintenance free ultra low cost powerful accurat...

Page 5: ...ou can also read the identifier and the PAC key using the QR code Install the wall mount carefully to the surface of your choosing e g to the wall Connect the tubes to the sensor When the tube connected to connector A red arrow is in low pressure and tube connected to the connector B is in higher pressure green arrow you will receive positive values ...

Page 6: ... Turn the device on by sliding the power switch to position I at the bottom of the device The switch is located inside of the opening Attach the device to the wall mount ...

Page 7: ... FALSE 0 3 UInt1 Active power control 1 ON 0 OFF 0 4 7 UInt4 Firmware version 1 15 1 0 7 UInt8 Temperature T 40 40C 85C 2 3 0 15 UInt16 Pressure difference P 10 500 500Pa 500Pa 0x2C 00101100Bin Full power TRUE Active power control On FW Version 2 Header 0x40 64Dec 64 40 24 C Temperature Pressure difference 0x1388 5000Dec 5000 10 500 0Pa ...

Page 8: ...s How often messages are sent can be adjusted with the settings Default settings when device has not been configured with downlink Uplink reporting period is 30minutes Adaptive Power Control is OFF Full transmit power is used If the Adaptive power control feature is set on the device will automatically adjust the transmit power to optimum level to save battery and create less unnecessary interfere...

Page 9: ...E BIT TYPE DESCRIPTION 0 0 5 Reserved set to 0 0 6 Boolean Active power control 1 On 0 Off 0 7 Boolean DL Reconfigure enable 1 TRUE 0 FALSE 1 0 7 Uint8 Update interval 5 min n 2 10min 24h Refer to Appendix 1 2 7 all Reserved set to 0 ...

Page 10: ...tric cables electric devices or selective windows Metallic roofs steel reinforced concrete underground location and other obstacles can dramatically reduce radio signal Check the operation mode of the device Incorrect downlink configuration will affect to behaviour of the product Ensure the configuration is properly done Connected Invention s customer support phone 358 10 3115800 email support con...

Page 11: ... min measuring interval Sensors Sensirion SDP810 500PA Environment Temperature 0 50 C Humidity 0 95 Pressure 500 500 Pa Radio configurations Sigfox 868 MHz RCZ1 902 MHz RCZ2 920 MHz RCZ4 Antenna Internal helical antenna Communication Uplink Downlink Certifications CE Sigfox P_010A_05D7_01 RC1 Class 0U P_010A_AAFA_01 RC2 Class 0U P_010A_1652_01 RC4 Class 0U Product code CIPRG 3007 R0401 RCZ1 CIPRG ...

Page 12: ...00000 205 8027000000000000 C027000000000000 210 8028000000000000 C028000000000000 215 8029000000000000 C029000000000000 220 802A000000000000 C02A00000000000 0 225 802B000000000000 C02B00000000000 0 230 802C000000000000 C02C00000000000 0 235 802D000000000000 C02D00000000000 0 240 802E000000000000 C02E000000000000 245 802F000000000000 C02F000000000000 250 8030000000000000 C030000000000000 255 803100...

Page 13: ...0 C080000000000000 655 8081000000000000 C081000000000000 660 8082000000000000 C082000000000000 665 8083000000000000 C083000000000000 670 8084000000000000 C084000000000000 675 8085000000000000 C085000000000000 680 8086000000000000 C086000000000000 685 8087000000000000 C087000000000000 690 8088000000000000 C088000000000000 695 8089000000000000 C089000000000000 700 808A000000000000 C08A00000000000 0 ...

Page 14: ... 0 1080 80D6000000000000 C0D600000000000 0 1085 80D7000000000000 C0D700000000000 0 1090 80D8000000000000 C0D800000000000 0 1095 80D9000000000000 C0D900000000000 0 1100 80DA000000000000 C0DA00000000000 0 1105 80DB000000000000 C0DB00000000000 0 1110 80DC000000000000 C0DC00000000000 0 1115 80DD000000000000 C0DD00000000000 0 1120 80DE000000000000 C0DE00000000000 0 1125 80DF000000000000 C0DF00000000000...

Reviews: